RS-...-PS
Thyristor speed controller
USER'S MANUAL
Страница 1: ...RS PS Thyristor speed controller USER S MANUAL...
Страница 2: ...field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country Safety require...
Страница 3: ...it avoid compression of the casing Deformation of the casing may result in motor jam and excessive noise Misuse of the unit and any unauthorised modifications are not allowed Do not expose the unit to...
Страница 4: ...hould be supervised to ensure that they do not play with the unit Connection to the mains must be made through a disconnecting device which is integrated into the fixed wiring system in accordance wit...
Страница 5: ...e operating status The controller allows the control of several motors as long as the total current consumption does not exceed the current limit of the controller All models have an optional non adju...
Страница 6: ...0 15 0 25 0 4 Max load current A 0 5 1 5 2 5 4 0 Rated current of the fuse A 0 63 1 5 2 5 4 0 Wire cross section mm2 max 2 5 Maximum ambient air temperature C 35 Weight kg 0 23 0 24 0 29 0 36 SEC clas...
Страница 7: ...EN 7 89 82 62 62 7 50 82 65 24 32 WHILE INSTALLING THE UNIT ENSURE CONVENIENT ACCESS FOR SUBSEQUENT MAINTENANCE AND REPAIR...
Страница 8: ...djustment trimmer Operating status indicator DESIGN AND OPERATING PRINCIPLE 89 82 62 62 7 50 82 65 24 32 The controller should be installed on a vertical wall indoors in a hidden mounting box Inspect...
Страница 9: ...ards Apply the mains voltage and switch on the controller Adjust the minimum fan speed at the end position of the control knob Turn of the controller Wait for the fan to stop Turn on the controller to...
Страница 10: ...ntroller Adjust the minimum fan speed at the end position of the control knob Turn of the controller Wait for the fan to stop Turn on the controller to the minimum speed the fan should rotate steadily...
Страница 11: ...t of dust lint etc Make sure that the external electrical leads are securely attached to the screwed terminals of the unit Replacing the fuse Return the fuse knob to its original position by turning i...
Страница 12: ...on Check the correctness of connection to power mains The fuse is broken Replace the fuse The fan does not rotate when the controller is on The minimum fan speed is not set correctly Adjust the minimu...
Страница 13: ...handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechan...
Страница 14: ...to get all the faults eliminated by the manufacturer by means of warranty repair at the factory free of charge The warranty repair includes work specific to elimination of faults in the unit operation...
Страница 15: ...r mains with a voltage different from the one stated in the user s manual Unit breakdown due to voltage surges in power mains Discretionary repair of the unit by the user Unit repair by any persons wi...
Страница 16: ...www ventilation system com V20 3EN 04 Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date...