Vents Quiet-Disc Скачать руководство пользователя страница 1

AXIAL FAN

User’s manual

www.ventilation-system.com

Quiet-Disc

EN

Содержание Quiet-Disc

Страница 1: ...AXIAL FAN User s manual www ventilation system com Quiet Disc EN...

Страница 2: ...Brief description 6 Operation guidelines 6 Fan options 7 Designation key 9 Mounting and set up 10 Operation indication 10 Fan setup 11 Technical maintenance 12 Storage and transportation regulations 1...

Страница 3: ...is correct at the time of the document s preparation The Company reserves the right to modify the technical characteristics design or configuration of its products at any time in order to incorporate...

Страница 4: ...QF automatic circuit breaker integrated into the fixed wiring system The gap between the circuit breaker contacts on all poles must be not less than 3 mm Check the unit for any visible damages of the...

Страница 5: ...containing spirits gasoline insecticides etc Do not close or block the intake or extract vents in order to ensure the efficient air flow Do not sit on the unit and do not put objects on it The unit is...

Страница 6: ...motor and the fan with the connecting diameter 150 mm is equipped with a double speed motor The Quiet Disc fan is equipped with a high powered motor The fan is equipped with a back valve that prevents...

Страница 7: ...on the switch for example a light switch the fan is switched on in a set turn on delay time period adjustable from 0 to 2 minutes After the switch is turned off the fan keeps operating for a set turn...

Страница 8: ...e up to 100 After no more motion is detected the fan keeps operating for a set turn off delay time period adjustable from 2 to 30 minutes For 150 and 150 Extra models Upon activation of the motion sen...

Страница 9: ...dditional options V pull cord switch T turn off delay timer T1 turn on and turn off delay timer VT pull cord switch and turn off delay timer TH humidity sensor VTH pull cord switch and humidity sensor...

Страница 10: ...against ingress of rainfalls and condensate inside the fan Fan installation with direct air discharge upwards is not allowed Fig 2 The fan mounting sequence is shown in Fig 3 11 The fan wiring diagram...

Страница 11: ...e fan turn off delay time turn the control knob off clockwise to increase and counter clockwise to decrease the turn off delay time respectively adjustable from 2 up to 30 minutes To adjust the humidi...

Страница 12: ...temperature range from 5 to 40 and relative humidity up to 70 Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion insulation and sealing deformation Use s...

Страница 13: ...re its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component T...

Страница 14: ...ower mains with a voltage different from the one stated in the user s manual Unit breakdown due to voltage surges in power mains Discretionary repair of the unit by the user Unit repair by any persons...

Страница 15: ...15 EN B D L L1 H 1 2 Dimensions mm D B H L L1 Quiet Disc 100 99 158 136 81 26 Quiet Disc 125 123 5 182 158 91 27 Quiet Disc 150 147 5 214 190 111 32 Quiet Disc Extra 150...

Страница 16: ...16 EN 3 4 5 6 7 8 9 10 11...

Страница 17: ...17 EN LT 1 N 3 L 2 L N S QF 12...

Страница 18: ...QF N 3 S S L 2 N 3 QF QF L 2 N 3 L N L N L N Quiet Disc 100 125 Quiet Disc 100 125 V The fan does not run S switch to ON or pull cord switch Fan runs S switch to OFF or pull cord switch 13 Quiet Disc...

Страница 19: ...on of turn on delay timer 0 2 minutes S switch is OFF during countdownof turn on delay timer Yes No Fan runs Activation of turn off delay timer 2 30 minutes S switch to OFF or pull cord switch Activat...

Страница 20: ...TH Quiet Disc 100 125 VTH The fan does not run S switch to ON or pull cord switch Fan runs S switch to OFF or pull cord switch Humidity exceeds set point Yes No Activation of turn off delay timer 2 3...

Страница 21: ...21 EN QF L N LT 1 L 2 N 3 Quiet Disc 100 125 TP The fan does not run Activation of turn off delay timer 2 30 minutes No motion detected Fan runs Motion detected 16...

Страница 22: ...switch to ON or pull cord switch Fan runs at speed 1 S switch to OFF or pull cord switch QF S LT 1 L 2 N 3 QF S N 3 QF LT 1 L 2 N 3 LT 1 L 2 L N L N L N Quiet Disc 100 125 Duo speed 2 Quiet Disc 100 1...

Страница 23: ...2 N 3 LT 1 L 2 N 3 L N L N L N Quiet Disc 100 125 Duo speed 1 and 2 Quiet Disc 100 125 Duo V speed 1 and 2 speed 1 and 2 The fan does not run S switch to ON or pull cord switch Fan runs at speed 1 Fan...

Страница 24: ...an runs at speed 1 Start of interval timer 6 12 or 24 hours Activation of turn off delay timer 60 seconds Fan runs at speed 1 Contact of the S switch or the pull cord switch is CLOSED Yes No Activatio...

Страница 25: ...econds Humidity exceeds set point No Fan runs at speed 1 Contact of the S switch or the pull cord switch is CLOSED Activation of turn on delay timer 60 seconds Humidity exceeds set point Yes No Contac...

Страница 26: ...ch to ON or pull cord switch Fan runs at speed 1 S switch to OFF or pull cord switch QF S QF S QF LT 1 L 2 N 3 LT 1 L 2 N 3 LT 1 L 2 N 3 L N L N L N Quiet Disc 150 Quiet Disc Extra 150 speed 2 Quiet D...

Страница 27: ...2 N 3 LT 1 L 2 N 3 Quiet Disc 150 Quiet Disc Extra ISO speed 1 and 2 Quiet Disc 150 Quiet Disc Extra ISOB speed 1 and 2 speed 1 and 2 The fan does not run S switch to ON or pull cord switch Speed swit...

Страница 28: ...speed when the humidity sensor is activated Operation mode 5 two speed The fan is turned off by default The fan starts operating at low speed when the switch is turned on If during the operation at lo...

Страница 29: ...s OFF during countdown of turn on delay timer Yes No Fan runs at speed 1 S switch to ON or pull cord switch The fan does not run S switch to ON or pull cord switch Activation of turn off delay timer 0...

Страница 30: ...witch is OFF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switch The fan does not run Activat...

Страница 31: ...timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switch The fan does not run Activation of turn on delay timer 0 2 minutes Fan run...

Страница 32: ...of turn off delay timer 2 30 minutes S switch is OFF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull...

Страница 33: ...f delay timer 2 30 minutes S switch is OFF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switc...

Страница 34: ...ity exceeds set point No Yes Activation of turn on delay timer 0 2 minutes Fan runs at speed 1 Fan runs at speed 1 Fan runs at speed 1 The fan does not run Fan runs at speed 2 Fan runs at speed 1 Fan...

Страница 35: ...peed 2 Fan runs at speed 2 Fan runs at speed 1 No motion detected Activation of turn off delay timer 2 30 minutes Activation of turn off delay timer 2 30 minutes Activation of turn off delay timer 2 3...

Страница 36: ...36 EN 33 34 35 36 37 38...

Страница 37: ...37 EN...

Страница 38: ...38 EN...

Страница 39: ...39 EN Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date...

Страница 40: ...V194EN 01 Certificate of acceptance The fan is recognized as serviceable Quiet Disc Extra Duo V 100 T White 125 T1 Red VT Vintage TH Aluminum Lacquer 150 VTH Chrome TP Black Sapphire...

Отзывы: