Vents CBF 110 DC T Скачать руководство пользователя страница 1

CBF 110 DC T/TH/TP

CBF 110 DC LIGHT T/TH/TP

CBF 150 DC T/TH/TP

CBF 150 DC LIGHT T/TH/TP

Centrifugal ceiling fan

USER’S MANUAL

Содержание CBF 110 DC T

Страница 1: ...CBF 110 DC T TH TP CBF 110 DC LIGHT T TH TP CBF 150 DC T TH TP CBF 150 DC LIGHT T TH TP Centrifugal ceiling fan USER S MANUAL...

Страница 2: ...to installing and operating the unit All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must b...

Страница 3: ...ectric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not allow children to operate the...

Страница 4: ...RY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION LOC...

Страница 5: ...nes described in this manual CBF150 DC T TH TP CBF110 DC T TH TP A E H d D L2 L1 B C A E H B L1 L2 d D h C b a A E C B D H h L1 A E C h B H L1 D b a CBF110 DC Light T TH TP CBF150 DC Light T TH TP h O...

Страница 6: ...150 Noise level 3 m dB A Sones from 23 0 3 up 25 0 7 from 23 0 3 up 29 1 0 Weight kg 6 4 5 3 6 2 5 1 IP X4 X4 SEC class B B only for the Light modifications TECHNICAL DATA CBF 110 150 DC T TH TP CBF...

Страница 7: ...motion is detected more the fan keeps running for a set turn off delay time adjustable from 1 to 90 minutes and the reverts to the initial operation status Humidity sensor TH If the indoor humidity ex...

Страница 8: ...TH models with a humidity sensor remove the protective cap from the grille prior to its installation Route the contact socket of the sensor TH or TP via the opening in the grille and connect the senso...

Страница 9: ...to one of the ceiling joists Installation between the ceiling joists Fixation between the ceiling joists using the mounting brackets Additional fastening holes in the fan casing may be used for mounti...

Страница 10: ...ower mains using durable insulated and heat resistant conductors cables and wires via the circuit breaker QF integrated into the house cabling system The external circuit breaker installation place mu...

Страница 11: ...up menu Once the button is pressed the indicator displays the turn on delay timer setting which can be edited with the buttons and Once the button is pressed again the setup menu is displayed again an...

Страница 12: ...M The maximum air flow value is limited to 110 or 150 CFM depending on the fan model 120 130 140 and 150 air flow values are not available for the fan with the air capacity 110 CFM Example 1 with thes...

Страница 13: ...BLE POSSIBLE REASONS TROUBLESHOOTING The fan does not get started No power supply Check the electric connections and the operation status of the circuit breaker Motor jam Turn the fan off Troubleshoot...

Страница 14: ...y for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packag...

Страница 15: ...dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual User s failure to ensure timely technical maintenance of...

Страница 16: ...nce with the provisions of all the applicable local and national construction electrical and technical codes and standards The unit operates normally as intended by the manufacturer Signature WARRANTY...

Страница 17: ...17 www ventilation system com...

Страница 18: ...18 CBF DC www ventilation system com...