USER’S MANUAL

Vents 

Brig HRV 200

Vents 

Brig HRV 300 

Heat Recovery Ventilator 

Содержание brig HRV 200

Страница 1: ...USER S MANUAL Vents Brig HRV 200 Vents Brig HRV 300 Heat Recovery Ventilator...

Страница 2: ...s Technical data Safety requirements Structure and operating logic Mounting and setting up Condensate drainage Unit connection to power mains Unit control Servicing and maintenance Troubleshooting Sto...

Страница 3: ...nd public premises as well as utilization of extract air heat energy to warm up supply purified air The unit is for ceiling mounting The unit is rated for continuous operation always connected to powe...

Страница 4: ...ntilator UNIT DESIGNATION KEY BASIC DIMENSIONS Unit type D A B C E F G H I Brig HRV 200 6 32 3 8 28 7 16 17 5 16 8 5 8 11 3 4 6 23 11 16 24 5 8 Brig HRV 300 8 40 5 8 36 3 4 17 5 16 8 5 8 12 3 4 6 7 16...

Страница 5: ...not connect clothes dryers or similar equipment to the ventilation system Do not operate the unit in the air and dust mixture environment Warning Mounting servicing connection and repair works of the...

Страница 6: ...er Then clean air flows through the heat recovery core and is supplied to the room by supply fan Thermal energy of warm extract air is transferred to clean intake fresh air and warms it up The extract...

Страница 7: ...with a summer block when no need for heat recovery 4 G4 supply air filter 5 G4 extract air filter 6 Drain pan 7 Drain hose included into delivery set 8 Frost protection thermostat While mounting the u...

Страница 8: ...drain system 5 with metal plastic or rubber pipes 2 and 4 The pipes must be sloped down at least by 3 Before starting operation of the unit fill the system with water and check that U trap is always...

Страница 9: ...in case of overload or short circuit To replace the thermal fuse disconnect the unit from power mains remove the overload or short circuit Remove the thermal fuse and check the unit Wiring diagram is...

Страница 10: ...trol fig 6 Up to five external control devices may be connected to the terminals 2 11 fig 7 that turn the unit to high speed ventilation in case of activation of any of the control devices Switch the...

Страница 11: ...es into the High Speed Mode 3 Humidistat The humidistat is used for indoor humidity control When indoor humidity level rises above the set point the unit changes into the High Speed Mode and runs with...

Страница 12: ...ou perform regular maintenance of the filters and the heat recovery core some dust and grease can get accumulated inside the fans and reduce the fan performance and supply air flow Clean the fans with...

Страница 13: ...tpoints Low air capacity Too low set rotation speed Check the speed control settings The filters fans or heat recovery core are clogged Clean or replace the extract filters clean the fans and the heat...

Страница 14: ...warranty is limited to the time period specified for the express warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you VENTS...

Страница 15: ...15...

Страница 16: ...V103EN 03 USA_120 _HVR 200 300...