READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT.

BEFORE MOUNTING, MAKE SURE THERE ARE NO VISIBLE DEFECTS ON THE UNIT, SUCH 

AS MECHANICAL DAMAGES, MISSING PARTS, IMPELLER JAMMING ETC.

WHEN MOUNTING THE UNIT, IT IS NECESSARY TO PROVIDE PROTECTION AGAINST 

CONTACT WITH HAZARDOUS ZONES OF THE FAN BY INSTALLING AIR DUCTS OF THE 

NECESSARY LENGTHS AND PROTECTIVE GRILLES.

MOUNTING MUST BE PERFORMED BY QUALIFIED SPECIALISTS ONLY, PROPERLY 

TRAINED AND QUALIFIED TO INSTALL AND MAINTAIN VENTILATION EQUIPMENT.

The unit is intended for mounting with round air ducts. The fan is installed between the air ducts.
The fan casing is equipped with fixing brackets for suspended mounting or for mounting on a horizontal or vertical surface.
While installing the unit ensure convenient access for subsequent maintenance and repair. Fasteners for fan mounting are not included 
in the delivery set and should be ordered separately. While choosing fasteners consider the material of the mounting surface as well as 
the weigh of the unit, refer to the Technical data section. Fasteners for unit mounting should be selected by a service technician.

The unit can be mounted in two operation positions, which makes mounting easier. For this, dismantle the fan handle first or set it to 
another position.
After choosing one of two positions, securely mount the brackets to the fan.

1.

2.

SUSPENDED MOUNTING

Install the fan on the threaded rods (not included in the delivery set).

WARNING! When mounting the fan on threaded rods, it is necessary to provide protection of the nuts against 

self-loosening.

Nut
Washer
Vibration absorbing 

rubber
Washer
Nut and lock nut

Threaded rod

Содержание Boost 355

Страница 1: ...Boost 355 Boost 400 Inline mixed flow fan USER S MANUAL...

Страница 2: ...ertificate 13 Warranty card 13 This user s manual is a main operating document intended for technical maintenance and operating staff The manual contains information about purpose technical details op...

Страница 3: ...a hazardous or explosive environment containing spirits gasoline insecticides etc Do not close or block the intake or extract vents in order to ensure the efficient air flow Do not sit on the unit and...

Страница 4: ...rnal switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility Precautions must be taken to avoid the back flow of gases into the room from the op...

Страница 5: ...res evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogeni...

Страница 6: ...Voltage V at 50 Hz 1 230 Power W 126 131 150 197 204 224 Current A 0 60 0 58 0 66 0 91 0 90 0 98 Maximum air flow m3 h 2090 2296 2485 2677 3136 3350 RPM min 1 1350 1400 1470 1320 1390 1446 Maximum tr...

Страница 7: ...izontal or vertical surface While installing the unit ensure convenient access for subsequent maintenance and repair Fasteners for fan mounting are not included in the delivery set and should be order...

Страница 8: ...cted the internal parts of the unit must be protected from ingress of foreign objects To prevent uncontrollable access to the fans the spigots may be covered with a protecting grille or other protecti...

Страница 9: ...ors cables wires The actual wire cross section selection must be based on the maximum load current maximum conductor temperature depending on the wire type insulation length and installation method Th...

Страница 10: ...ons Disconnect the air ducts from the fan Clean the fans with a soft brush cloth vacuum cleaner or compressed air Do not use water aggressive solvents or sharp objects as they may damage the impeller...

Страница 11: ...up after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours TROUBLESHOOTING Problem Possible reasons Troubleshooting The fan s do es not start...

Страница 12: ...Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual includin...

Страница 13: ...N CERTIFICATE The Boost_________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full...

Страница 14: ...14 Boost www ventilation system com...

Страница 15: ...15 www ventilation system com...

Страница 16: ...V208EN 04...

Отзывы: