MANUFACTURER’S WARRANTY

The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby 
declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European 
Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking 
Council Directive 93/68/EEC. This certificate is issued following test carried out on samples of the product referred to above.
The manufacturer hereby warrants normal operation of the unit for 24 months after the retail sale date provided the user's observance 
of the transportation, storage, installation, and operation regulations. Should any malfunctions occur in the course of the unit operation 
through the Manufacturer's fault during the guaranteed period of operation, the user is entitled to get all the faults eliminated by the 
manufacturer by means of warranty repair at the factory free of charge. The warranty repair includes work specific to elimination of faults 
in the unit operation to ensure its intended use by the user within the guaranteed period of operation. The faults are eliminated by means 
of replacement or repair of the unit components or a specific part of such unit component.

The warranty repair does not include: 

•  routine technical maintenance
•  unit installation/dismantling 
•  unit setup
To benefit from warranty repair, the user must provide the unit, the user's manual with the purchase date stamp, and the payment 
paperwork certifying the purchase. The unit model must comply with the one stated in the user’s manual. Contact the Seller for warranty 
service. 

The manufacturer’s warranty does not apply to the following cases:

•  User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing 

component parts previously dismounted by the user.

•  Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user's manual.
•  User’s failure to ensure timely technical maintenance of the unit.
•  External damage to the unit casing (excluding external modifications as required for installation) and internal components caused 

by the user.

•  Redesign or engineering changes to the unit.
•  Replacement and use of any assemblies, parts and components not approved by the manufacturer.
•  Unit misuse.
•  Violation of the unit installation regulations by the user.
•  Violation of the unit control regulations by the user.
•  Unit connection to power mains with a voltage different from the one stated in the user's manual.
•  Unit breakdown due to voltage surges in power mains.
•  Discretionary repair of the unit by the user.
•  Unit repair by any persons without the manufacturer’s authorization.
•  Expiration of the unit warranty period.
•  Violation of the unit transportation regulations by the user.
•  Violation of the unit storage regulations by the user.
•  Wrongful actions against the unit committed by third parties.
•  Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).
•  Missing seals if provided by the user’s manual.
•  Failure to submit the user’s manual with the unit purchase date stamp.
•  Missing payment paperwork certifying the unit purchase.

FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND 

TROUBLE-FREE OPERATION OF THE UNIT.

USER’S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION 

OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL WITH THE 

PURCHASE DATE STAMP.

Содержание Boost 355

Страница 1: ...Boost 355 Boost 400 Inline mixed flow fan USER S MANUAL...

Страница 2: ...ertificate 13 Warranty card 13 This user s manual is a main operating document intended for technical maintenance and operating staff The manual contains information about purpose technical details op...

Страница 3: ...a hazardous or explosive environment containing spirits gasoline insecticides etc Do not close or block the intake or extract vents in order to ensure the efficient air flow Do not sit on the unit and...

Страница 4: ...rnal switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility Precautions must be taken to avoid the back flow of gases into the room from the op...

Страница 5: ...res evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogeni...

Страница 6: ...Voltage V at 50 Hz 1 230 Power W 126 131 150 197 204 224 Current A 0 60 0 58 0 66 0 91 0 90 0 98 Maximum air flow m3 h 2090 2296 2485 2677 3136 3350 RPM min 1 1350 1400 1470 1320 1390 1446 Maximum tr...

Страница 7: ...izontal or vertical surface While installing the unit ensure convenient access for subsequent maintenance and repair Fasteners for fan mounting are not included in the delivery set and should be order...

Страница 8: ...cted the internal parts of the unit must be protected from ingress of foreign objects To prevent uncontrollable access to the fans the spigots may be covered with a protecting grille or other protecti...

Страница 9: ...ors cables wires The actual wire cross section selection must be based on the maximum load current maximum conductor temperature depending on the wire type insulation length and installation method Th...

Страница 10: ...ons Disconnect the air ducts from the fan Clean the fans with a soft brush cloth vacuum cleaner or compressed air Do not use water aggressive solvents or sharp objects as they may damage the impeller...

Страница 11: ...up after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours TROUBLESHOOTING Problem Possible reasons Troubleshooting The fan s do es not start...

Страница 12: ...Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual includin...

Страница 13: ...N CERTIFICATE The Boost_________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full...

Страница 14: ...14 Boost www ventilation system com...

Страница 15: ...15 www ventilation system com...

Страница 16: ...V208EN 04...

Отзывы: