Instruction Manual
A detailed explanation of the functions and features of your new Ventis system
AUTO
19
1800 80 20 80
18
47
%RH
MID
Страница 1: ...Instruction Manual A detailed explanation of the functions and features of your new Ventis system AUTO 19 1800 80 20 80 18 47 RH MID ...
Страница 2: ...800 80 20 80 should you require help with your Ventis Home Ventilation system The Team at Important Safety Instructions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their s...
Страница 3: ...aintenance 3 4 5 6 9 11 14 15 17 19 20 AUTO FLUSH OFF Explained Modes Drying Heating Cooling Ventilation LO MID HI 14 Controller Button Functions Increase Set Point Select Item Above Decrease Set Point Select item below Exit Menu Return to previous screen Enter Menu Increment Value Scroll between operating modes OFF AUTO FLUSH OFF ...
Страница 4: ...en the System Fan is running Selected Circulation Level LO MID HIGH Fan speed bar graph Filter Change Warning Auto Whirly Status Only displayed if fitted Room Temperature Relative Humidity Source Temperature Appears in multiple locations Air Source Display Shows currently selected source Colour indicates mode Enabled Modes DRYING HEATING COOLING VENTILATING Error Display An error condition has bee...
Страница 5: ...Mode and Air Source Symbols DRYING HEATING COOLING VENTILATING HEATING ACTIVE HEATING ENABLED HEATING DISABLED FILTER CHANGE DUE FILTER CHANGE OVERDUE FAULT HAS OCCURRED MODE DISPLAYS AIR SOURCE DISPLAYS ...
Страница 6: ...s in the settings first wake up the control panel by pushing any button The controller will light up to its brightest setting when it is activated AUTO MODE means the Ventis is On and will operate Automatically FLUSH MODE means the Ventis fan will run at maximum speed for up to two hours OFF MODE is a manual override setting and means the Ventis is off regardless of your setting and roof space tem...
Страница 7: ...ur desired temperature set point is available The fan and fan speed bar graph will appear when the fan is on along with Heating Cooling or Ventilating icons show the reason the fan is running The source will be displayed Increase Set Point Decrease Set Point To Source Humidity Display To Main Menu Change to Flush ...
Страница 8: ...isture in the home burnt toast cooking smells steam cleaning etc The fan bar graph will appear at max speed You can change the FLUSH mode air source as shown below The source will be displayed The set Point is ignored and is hidden Change to previous source Change to next source To Humidity Display To Main Menu Change to OFF Mode MID ...
Страница 9: ...an Auto Whirly and Dampers are disabled Room temperature and Humidity continue to be displayed The set Point is displayed and may be changed Increase Set Point Decrease Set Point To Humidity Display To Main Menu Change to AUTO Mode ...
Страница 10: ...ellipsis indicate a sub menu is available on this line Please see all sub menus explained on the following pages Select item above Select item below Exit to Main Screen Enter selected menu Set Modes Menu The Mode Menu is used to enable or disable Drying Heating Cooling and Ventilation Modes Drying Heating Cooling Ventilation Boost Select item above Select item below Exit to Main Menu Change select...
Страница 11: ...y any Ventis service technician Select item above Select item below Exit to Main Menu Change selected value Filter Details Menu The filter life remaining is displayed as a percentage from 100 down to 0 Your screen will now show filter life remaining 100 20 Filter OK 19 1 Filter Change Due 0 Filter Change Overdue The Filter Reset Menu is enabled by pressing the and buttons simultaneously Once highl...
Страница 12: ...ive humidity above which drying is enabled Installation Menu The Installation Menu allows the User to observe details about unit operation Fault Code Fault Code is any previously cleared error code normally 0 Product It displays the installed product configuration ie CO Ceiling Outside Configure no longer showing on V2 43 and above Live Test Live test runs through an automatic test of all attached...
Страница 13: ...fits of the Ventis system It should only be used when condensation or moisture is a problem To set the humidity Set Point If you home do not have excess moisture problems then the Humidity Set point may be left at 50 and the Drying Mode turned off If you wish to reduce the moisture level in your home turn Drying Mode on Now take note of the room Relative Humidity RH between noon and 6pm on any giv...
Страница 14: ... low speed that shifts the room temperature away from the desired set point IMPORTANT Extended use of Ventilating mode particularly with Hi Boost could increase your energy bills by competing with other heating or cooling systems in your home BOOST Set the Boost level to increase the activity of your Ventis system LO This mode is a lower airflow setting and creates the benefit of low energy usage ...
Страница 15: ...up to 100 operating speed HIGH C3 In this mode the Ventis will only operate when the roof is at least 1 degree more desirable than your home but taking your house temperature towards your Set Point It takes a further 1 degree for the fan to ramp up to 100 operating speed Selected MID Circulation Level LO ECO MID HIGH Circulation HIGH is desirable for homes suffering from Condensation and severe Mo...
Страница 16: ...en press the button to reach Humidity Display HUMIDITY Display The Source Humidity Display shows the relative humidity measured at each available air source The room relative hu midity and Humidity Set Point are also displayed All values are in Relative Humidity Ceiling Outside Transfer Floor Back to Main Screen Back to Main Screen To DEW PT display Back to Main Screen ...
Страница 17: ...Back to Main Screen Back to Main Screen To ABS Display To HUMIDITY Display Source Absolute Humidity Display The Source Absolute Humidity Display shows the calculated water content of each available air source The calculated room water content is also displayed All values are in grams of H2O per cubic metre g m3 Ceiling Outside Transfer Floor Back to Main Screen Back to Main Screen Back to Main Scr...
Страница 18: ...ller by the Ventis Install team so there is nothing on the control panel that you need to worry about to get it operational It is fully automatic and will only operate when the roof cavity is too warm to provide any cooling benefit Your Auto Whirly is working when you see the small fan icon on the right of the roof image You will see it in operation through the warm summer months when it helps coo...
Страница 19: ...idity sensors that operate dampers to choose the best source of air for either cooling or warming your home Typically in summer the Auto Cooler will choose the outside source eave or roof vent for cooling your home at night when the sun goes down During winter the dampers will switch to the roof to harvest the warm air inside the roof space 18 ...
Страница 20: ... In summer Heating should be disabled This will prevent the Ventis System competing with other air heaters or coolers Control Heating and Cooling modes from the Modes Menu A step by step instruction video is available on our web site www ventis com au on how to change the setting from Winter to Sumer Filer Change Requirement Filters need replacing approximately every 12 months The system will let ...
Страница 21: ...omer Firmware Version Number Times out after 5 seconds Planet Innovation Copyright Fault Screen Fault Display The Fault Display appears if a persistent error occurs Users should note the Fault Number when reporting errors for service The TITLE and Fault Description may assist the user is self diagnosing and rectifying the problem Pressing any key will exit the error screen if possible Some errors ...
Страница 22: ...oom is dominated by the solid surfaces in the room the air will initially cold to near the existing room temperature If the air cools below its dewpoint condensation will occur on cold surfaces such as glass plaster board The Ventis has steam up prevention enabled in AUTO mode operating This can be overridden by using the FLUSH mode at the users discretion Guarantee Our goods come with guarantees ...
Страница 23: ...VENTILATION BOOST o o MID MID For both OFF and AUTO modes Increase Set temperature Decrease Set temperature Select item above Previous Source Change selected value Next Source Select item above Select item below Screen Navigation ...
Страница 24: ...1800 80 20 80 www ventis com au H O M E V E N T I L AT I O N July 2020 ...