The lubrication interval is application-dependent. You may need to lubricate more frequently depending on the duty cycle, usage, and environment. If the
lubricant appears to be dispersed before this point or has become dry or crusted, the maintenance interval should be reduced.
Before lubrication:
Clean the cover strip using isopropyl alcohol.
Inspect the strip for any damage. If damage is present contact us for the appropriate replacement parts and procedure.
Lubrication Procedure:
After cleaning and inspecting the cover strip lubricate it by adding grease to the cover strip surface.
Manually move the gantry back and forth, ensuring that a light layer of grease is distributed accross the cover strip.
Wipe off excess grease.
Figure 10: Green arrows point to suggested locations for application of grease to the cover strip.
Enclosed Ball Screw Actuator (MO-LM-039-XXXX) & Enclosed Lead Screw Actuator (MO-LM-047-
XXXX)
Figure 11: MO-LM-039-XXXX, Enclosed Ball Screw Actuator.
When to lubricate (Bearing):