background image

INSTRUCTION MANUAL 

 

 

 

(This photo is for reference only; it does not mean you are purchasing an identical product.   

Fan picture is for illustration purposes only. Styles may vary according to the particular model.) 

 

Ceiling Fan Installation Manual, Rev 1.0 

 

HARMONY II SERIES 

Models: 

HAR1204WH, HAR1204WH-L, HAR1204TI, HAR1204TI-L

 

 

 

 

 

INSTALLATION 

 

OPERATION 

 

MAINTENANCE 

 

WARRANTY INFORMATION 

 

 

 

 

CAUTION

 

Read Instructions Carefully 

For Safe Installation and   

Fan Operation

 

Содержание HAR1204 Series

Страница 1: ...s for illustration purposes only Styles may vary according to the particular model Ceiling Fan Installation Manual Rev 1 0 HARMONY II SERIES Models HAR1204WH HAR1204WH L HAR1204TI HAR1204TI L INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION Read Instructions Carefully For Safe Installation and Fan Operation ...

Страница 2: ...s standard Please note warranty will be void if installation is without an all pole disconnection incorporated in the fixed wiring in accordance with the wiring rules Example If a fan is connected to a circuit that can be isolated via an all pole safety switch at the switchboard then this is considered to be an all pole disconnection to the ceiling fan electrical circuit meeting the requirements o...

Страница 3: ...ottom cover x 1 2 Pre assembled fan motor down rod canopy and bottom cover x 1 3 Blades x 4 3 Blades x 4 4 Wall switch x 1 4 Wall switch x 1 5 Balancing kit x 1 5 Balancing kit x 1 6 Blade screws x 9 1 x spare 6 Blade screws x 9 1x spare 7 Wooden screws for mounting bracket x 2 7 Wooden screws for mounting bracket x 2 8 Plastic anchors x 2 8 Plastic anchors x 2 9 Light kit x 1 LED driver LED panel...

Страница 4: ...oist or structure that is capable of carrying a load of at least 30kg with the two long screws provided Ensure at least 30mm of the screw is threaded into the support NOTE The bracket screws provided are for use with wooden structures only For structures other than wood the appropriate screw type MUST be used Angled Ceiling Installation This fan hanging system supports a maximum 18 degree angled c...

Страница 5: ...n operation Fig 4 BLADE INSTALLATION BLADE ATTACHMENT Fig 5 1 Remove the top motor housing from the fan body by turning the top motor housing anticlockwise 2 Insert the blade into the square slot of the motor 3 Secure the blade on the bracket by using 2 motor screws ensuring they are tightened simultaneously 4 Once completed repeat the process on the remaining blades 5 Replace the top motor housin...

Страница 6: ...LECTRICIAN NOTE AN ADDITIONAL ALL POLE DISCONNECTION MUST BE INCORPORATED IN THE FIXED WIRING IN ACCORDANCE WITH THE WIRING RULES NOTE Wiring diagram includes the light kit wiring The light wiring diagram and switch is omitted when no light kit is used with the ceiling fan USE WITH WALL SWITCH WIRING DIAGRAM Fig 6 ...

Страница 7: ...7 USE WITH REMOTE WIRING DIAGRAM REMOTE sold separately 1 Remote without plugs 2 Remote with plugs Fig 8 Fig 7 ...

Страница 8: ... the canopy and that the wires are not damaged during this step Secure the canopy to the hanger bracket using the screws provided How to replace the LED driver For models with light kit NOTE Always turn OFF the power at the mains switch before attempting to replace the LED driver Loosen the screw A to lift the top housing B Replace the LED driver by unplugging the connectors C D Reposition the top...

Страница 9: ...s switch before attempting to replace the LED panel 1 Use a slotted screwdriver to dis assemble the plastic diffuser carefully 2 Loosen the 4 screws B and keep the screws Replace the LED panel by unplugging the connectors A 3 Re tighten the 4 screws re assemble the plastic diffuser Fig 12 Fig 11 ...

Страница 10: ...CTION Your ceiling fan can operate either in fan mode or reverse fan mode SUMMER Mode The reverse switch should be in the left SUMMER position to rotate the fan in an anticlockwise direction The airflow will be directed downwards for cooling in summer WINTER Mode The reverse switch should be in the right WINTER position to rotate the fan in a clockwise direction The airflow will be directed upward...

Страница 11: ...l Please allow a 24 hour breaking in period most noises associated with a new fan disappear during this time Please note that this is not a product fault and as such is not covered under warranty All electric motors are audible to some extent CARE AND CLEANING Periodic cleaning of your ceiling fan is the only maintenance required Use a soft brush or lint free cloth to avoid scratching the paint fi...

Страница 12: ...tenance can reduce or prevent this problem Night Noises This is the biggest cause of service calls which are outside the manufacturer s warranty If a fan has a fault then it would be noticeable at ALL TIMES Obviously when everything is quiet at night you will be more inclined to hear small noises which may not be noticeable at other times Even slight signals super imposed in your electricity suppl...