background image

Page 5

L114A 0808A

VENTING

ACCESSORIES

6” RECTANGULAR DUCT PIPE

MODEL

DIM

VP507

6” x 8 ½”

24”

8 ½”

6”

ROUND DUCT PIPE

MODEL

DIM

VP500

VP501

VP502

6” Round

7” Round

8” Round

36”

6”

7”

8”

3 ¼” RECTANGULAR DUCT PIPE

MODEL

DIM

VP504

VP505

VP506

3 ¼” x 10”

3 ¼” x 12”

3 ¼” x 16”

30”

10”

12”

16”

3 ¼”

OFFSET L & R TRANSITION

FOR ISLAND BLOWERS

MODEL

DIM

VP542

VP543

Top Left

Top Right

8”

12”

5”

16”

SIDE VENT TRANSITION L & R

FOR ISLAND BLOWERS

MODEL

DIM

VP544

VP545

Left Side

Right Side

19”

8”

16”

5”

6” x 8 ½” COLLAR

MODEL

DIM

VP537

6” x 8 ½”

11 ½”

6” x 8 ½”

Opening

9”

OFFSET KIT - RECTANGULAR

MODEL

DIM

VP550

6” Rnd to 3 ¼” x 10”

16”

11”

6”

11”

3 ¼”

10”

STANDARD ISLAND TRANSITION

MODEL

DIM

VP565

5” x 16” to 8”

8”

9”

16”

5”

CLUSTER BLOWER TRANSITION

MODEL

DIM

VP564

8” & 8” to 12”

18 ½”

12”

11 ¼”

“Y” TRANSITION

MODEL

DIM

VP517

VP518

VP551

8” & 8” to 12”

6” & 8” to 12”

6” & 8” to 10”

18”

10”

12”

3 ¼” x 10” BACK VENT ELBOW

MODEL

DIM

VP559

3 ¼” x 10”

4 ¼”

10”

14”

3 ¼”

3 ¼”

MULTI-BLOWER TRANSITION

MODEL

DIM

VP562

VP563

6” & 8” to 10”

8” & 8” to 12”

VP562 - 17 ½”

VP563 - 16 ½”

10”

12”

VP562 - 23 ¼”

VP563 - 30 ½”

3 ¼” x 10” TO 7” TRANSITION

MODEL

DIM

VP521

3 ¼” x 10” to 7”

7”

7 ½”

3 ¼”

10”

LOW PROFILE ROOF JACK

(MAXIMUM 4/12 PITCH)

MODEL

DIM

6 ½”

VP539

VP540

VP541

6” Round

7” Round

8” Round

16 ¾”

16 ¾”

LOW PROFILE ROOF JACK

(MAXIMUM 4/12 PITCH)

MODEL

DIM

10 ½”

VP552

VP553

10” Round

12” Round

22 ½”

20 ¾”

ADJUSTABLE ELBOW

MODEL

DIM

VP513

VP514

VP515

6” Round

7” Round

8” Round

6”

7”

8”

VP513 - 8 ½”

VP514 - 9 �⁄��”

VP515 - 10 �⁄�”

BACK/SIDE VENT ELBOW

MODEL

DIM

VP561

8” to 6” x 8 ½”

12”

6”

16”

8” Round

8 ½”

WALL LOUVER

MODEL

DIM

6”

7”

8”

8 �⁄�”

VP526

VP527

VP528

6” Round

7” Round

8” Round

Back

View

1 ½” Flange

WALL LOUVER

MODEL

DIM

11”

11”

VP554

10” Round

Back

View

1 ½” Flange

WALL LOUVER

MODEL

DIM

13”

13”

VP555

12” Round

Back

View

1 ½” Flange

RECTANGULAR WALL LOUVER

MODEL

DIM

3 ¼”

10”

VP538

VP560

6” x 8 ½“

3 ¼” x 10”

8 ½”

6”

1 ½”

 FLANGE

2” FLANGE

OFFSET KIT - ROUND

MODEL

DIM

VP529

6” Rnd to 7” Rnd

16”

11”

6”

7”

10 ½”

6” & 8” COLLAR

MODEL

DIM

VP533

VP535

6” Round

8” Round

2” La

r

ge

r

Than Cutout

6” Round

8” Round

2” La

r

ge

r

Than Cutout

Содержание SLH6-K

Страница 1: ...he service disconnecting means to prevent power from being switched on accidentally during installation B When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent ba...

Страница 2: ...angled turns Instead use smooth gradual turns such as adjustable elbows or 45 degree angled turns For duct runs over 20 feet increase the duct diameter by one inch for every ten feet of duct A 90 degree elbow is equal to 5 feet of duct Using Vent A Hood roof jacks or wall louvers back page will ensure proper efficiency Airflow must not be restricted at the end of the duct run Do not use screen wir...

Страница 3: ...izontal discharge by exchanging the discharge adapter on top of the hood 4 screws with the discharge cover on the back of the hood 2 screws Use duct tape to seal the discharge adapter and discharge cover to the hood 5 IF THE HOOD IS TO BE BACK VENTED PROCEED DIRECTLY TO STEP 6 Install the duct from the outside of the home down to the location of the hood exhaust outlet allowing room for the VP521 ...

Страница 4: ... wall prior to installing the hood Starting 2 1 8 above the bottom edge of the hood cut a hole 3 1 2 high x 10 1 4 wide see diagram at right 11 Install the duct from the outside of the home to the duct access hole in the wall Where possible use duct tape to seal joints 12 While aligning the duct and guiding the wires position the hood under the cabinet The duct should connect together as the hood ...

Страница 5: ...9 3 x 10 4 10 14 3 3 MULTI BLOWER TRANSITION MODEL DIM VP562 VP563 6 8 to 10 8 8 to 12 VP562 17 VP563 16 10 12 VP562 23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 10 VP552 VP553 10 Round 12 Round 22 20 ADJUSTABLE ELBOW MOD...

Отзывы: