Read and Save These Instructions 

All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS 

JDIH ISLAND RANGE HOOD

Read All Instructions Thoroughly Before Beginning Installation

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified person(s) 

in  accordance  with  all  applicable  codes  and  standards,  including  fire-

rated construction. Switch power off at service panel and lock the service 

disconnecting means to prevent power from being switched on accidentally 

during installation.

B.  When cutting or drilling into wall or ceiling, do not damage electrical wiring 

and other hidden utilities.

C. Ducted fans must always be vented to the outdoors.

D. Sufficient air is needed for proper combustion and exhausting of gases 

through  the  flue  (chimney)  of  fuel  burning  equipment  to  prevent  back 

drafting.  Follow  the  heating  equipment  manufacturer’s  guideline  and 

safety standards such as those published by the National Fire Protection 

Association (NFPA), and the American Society for Heating, Refrigeration 

and Air Conditioning Engineers (ASHRAE), and local code authorities.

E.  ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to 

a maximum of 15 CFM per 100 square feet of occupiable space, unless a 

back drafting test is performed or make-up air is provided. Consult a local 

HVAC engineer for make-up air evaluation.

WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL 

DUCTWORK

Содержание JDIH ISLAND

Страница 1: ...to wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire P...

Страница 2: ...nd or equivalent 50 sq in VP565 Included Island Cluster T400 12 round or equivalent 113 sq in VP564 Included Ducting Requirements NEVER reduce the duct size Do not use flexible or corrugated duct This type of duct will restrict airflow and reduce performance Only use smooth galvanized metal duct Make the duct run as short and as straight as possible with as few turns as possible Avoid sharp angled...

Страница 3: ...er Install the duct cover to the load bearing framework in the ceiling using appropriate hardware through the four inside corner mounting flanges on the top of the duct cover 4 Install the duct from the outside of the home down to the location of the exhaust outlet on the top of the transition plus 1 This will allow the transition to engage 1 inside of the duct Consult the connection diagrams on n...

Страница 4: ...ack draft dampers from the top side of the hood To remove the blower housings unsnap the suitcase latches one on each side of the housing The housings should be pulled forward and gently tipped to clear the blower wheels and then out of the hood Warning Make sure power is off and locked at the service disconnecting means on the service panel during installation 7 Remove the blower deck assembly by...

Страница 5: ...eck assembly into the hood using the 12 screws previously removed in Step 7 12 Replace the blower housings and the blower shields Make sure that the dampers open and close smoothly 13 Refer to Owner Maintenance Guide Operating Instructions for proper hood operation Test all blower and light functions to ensure they are operating properly Model Volts Amps Hz RPM CFM SP 0 0 Equivalent CFM CFM SP 0 1...

Страница 6: ... 23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 10 VP552 VP553 10 Round 12 Round 22 20 ADJUSTABLE ELBOW MODEL DIM VP513 VP514 VP515 6 Round 7 Round 8 Round 6 7 8 VP513 8 VP514 9 9 16 VP515 10 5 8 BACK SIDE VENT ELBOW MODEL ...

Отзывы: