Vent Xpress Broan Elite EPD61 Скачать руководство пользователя страница 1

 #2 Chootoo Road, South Aranguez, San Juan, Trinidad 

EPD61 SERIES

HB0120

INTENDED FOR DOMESTIC COOKING ONLY

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.

HOMEOWNER: USE AND CARE INFORMATION ON PAGES 9 

AND

 10.

READ AND SAVE THESE INSTRUCTIONS

Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711
Venmar Ventilation ULC; Drummondville, Québec www.broan.ca 877-896-1119

REGISTER YOUR PRODUCT ONLINE AT: www.broan.com/register

SV20571 rev. 06

INSTALLATION INSTRUCTIONS

S

UITABLE

 

FOR

 

USE

 

IN

 

DAMP

 

LOCATIONS

 

WHEN

 

INSTALLED

 

IN

 

A

 

GFCI PROTECTED BRANCH-CIRCUIT.

I

NTENDED

 

FOR

 

OUTDOOR

 

COVERED

 

PATIO

 

OR

 

LANAI

 

AREA

.

2

TO REDUCE THE RISK OF FIRE, ELECTRIC 
SHOCK OR INJURY TO PERSONS, 
OBSERVE THE  FOLLOWING:

1.

Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact
the manufacturer at the address or telephone 
number listed in the warranty.

2.

Before servicing or cleaning unit, switch
power off at service panel and lock service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be locked, 
securely fasten a prominent warning device,
such as a tag, to the service panel.

3.

Installation work and electrical wiring must be 
done by qualified personnel in accordance with 
all applicable codes and standards, including 
fire-rated construction codes and standards.

4.

Sufficient air is needed for proper combustion 
and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent 
backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards 
such as those published by the National
Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and 
the local code authorities.

5.

When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.

6.

Ducted fans must always be vented to the outdoors.

7.

Do not use this unit with any additional
solid-state speed control device.

8.

To reduce the risk of fire, use only metal
ductwork.

9.

This unit must be grounded and protected by a 
GFCI.

10.

 Suitable for use in damp locations only when 
installed in a GFCI PROTECTED branch-circuit.

11.

 This unit is not designed to be used with a 

charcoal grill.

12.

 

When applicable local regulations comprise

more restrictive installation and/or certification 
requirements, the aforementioned requirements 
prevail on those of this document and the installer
agrees to conform to these at his own expense.

TO REDUCE THE RISK OF A RANGE TOP 
GREASE FIRE:

a)

Never leave surface units unattended at high 
settings. Boilovers cause smoking and greasy 
spillovers that may ignite. Heat oils slowly on 
low or medium settings.

b)

Always turn hood ON when cooking at high heat 
or when flambeing food (i.e.: Crêpes Suzette, 
Cherries Jubilee, Peppercorn Beef Flambé).

c)

Clean ventilating fans frequently. Grease should 
not be allowed to accumulate on fan, filters or in 
exhaust ducts.

d)

 Use proper pan size. Always use cookware

appropriate for the size of the surface element.

1.

For general ventilating use only. Do not use to 
exhaust hazardous or explosive materials and 
vapors.

2.

To avoid motor bearing damage and noisy and/
or unbalanced impellers, keep drywall spray, 
construction dust, etc. off power unit.

3.

Your hood motor has a thermal overload
which will automatically shut off the motor if 
it becomes overheated. The motor will restart 
when it cools down. If the motor continues to 
shut off and restart, have the hood serviced.

4.

For best capture of cooking impurities, the
bottom of the hood must be located at a minimum
distance of 36” above cooking surface.

5.

Two installers are recommended because of
the large size and weight of this hood.

6.

To reduce the risk of fire and to properly
exhaust air, be sure to duct air outside — Do 
not exhaust air into spaces within walls or
ceiling or into attics, crawl space or garage. 

7.

This product is equipped with a thermostat
which may start blower automatically. To reduce 
the risk of injury and to prevent power from 
being switched on accidentally, switch power off 
at service panel and lock or tag service panel.

8.

Please read specification label on product for 
further information and requirements.

   WARNING

CAUTION

TO REDUCE THE RISK OF INJURY TO 
PERSONS IN THE EVENT OF A RANGE TOP 
GREASE FIRE, OBSERVE THE FOLLOWING*:

1.

SMOTHER FLAMES with a close-fitting
lid, cookie sheet or metal tray, then turn off 
the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT 
IMMEDIATELY, EVACUATE AND CALL THE
FIRE DEPARTMENT.

2.

NEVER PICK UP A FLAMING PAN — You may 
be burned.

3.

DO NOT USE WATER, including wet dishcloths 
or towels — This could cause a violent steam 
explosion.

4.

Use an extinguisher ONLY if:

A.

You own a Class ABC extinguisher and you 
know how to operate it.

B.

 The fire is small and contained in the area 

where it started.

C.

The fire department has been called.

D.

  You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by 
NFPA.

    WARNING

3

- EPD61 SERIES RANGE HOOD SYSTEM -

M

ODEL

 437

(H

IGH

 

CAPACITY

 

ROOF

 

CAP

)

HL0186

M

ODEL

 441

(10’’ 

ROUND

 

WALL

 

CAP

)

M

ODEL

 418

(10” 

ROUND

 

ADJUSTABLE

 

ELBOW

OPTIONAL

)

OPTIONAL
WALL EXTENSION 
AWEPD SERIES

D

UAL

 B

LOWER

 

(

INCLUDED

)

EPD61 SERIES

RANGE HOOD

10” 

ROUND

 

ADAPTER

 

(

INCLUDED

)

M

ODEL

 410

(10” 

ROUND

 

DUCT

 

— 2 

FT

SECTIONS

)

OPTIONAL

DECORATIVE FLUE

AEEPD SERIES

4

1.  INSTALL DUCTWORK AND ELECTRICAL WIRING

Plan where and how the ductwork will be installed.

A straight, short duct run will allow the hood to perform most 
efficiently.

Install proper-sized ductwork, elbows and roof or wall cap. 
Connect metal ductwork to cap and work back towards the 
hood location. Use 2” metal foil duct tape to seal duct joints.

Run 3-wire power supply cable to installation location.

For best capture of cooking impurities, the bottom of 
the hood must be located at a minimum distance of 36” 
above cooking surface.

18"

W

ALL

 

CAP

36" 

MINIMUM

 

ABOVE

COOKING

 

SURFACE

16" 

TO

TOP

 

OF

 

WOOD

MOUNTING

 

STRIP

O

PTIONAL

 

DECORATIVE

 

FLUE

 

OR

 

SOFFIT

HH0182A

R

OOF

 

CAP

10" R

OUND

 

DUCT

10" R

OUND

 

ELBOW

10" R

OUND

ADAPTER

CAUTION

This range hood is intended for outdoor covered patio or lanai area. As with all electric
appliances, this unit must be protected from the effects of weather.

  WARNING

!

This range hood is not designed for use with a charcoal grill.

   WARNING

!

The power cable must be a GFCI protected 
branch circuit.

2. PREPARE INSTALLATION

NOTE:  Before proceeding to the installation, check the contents of the box. If items are missing or 

damaged, contact the manufacturer. 

Make sure that the following items are included:

-

Range 

hood

-  Wood strip (attached to back of hood)

-

Installation 

manual

-

Accessories 

including:

•  Baffle filter with handles: 3 for 36” width model, 4 for 42” and 48” width models 

and 5 for 60” width model

•  10” round adapter (taped inside the hood)

•  Bag of parts:  3 waterproof wire connectors, 2 no. 8 x 5/8’’ screws, 6 no. 10 x 2’’ hex head screws,

4 no. 10 x 2” flat head screws, 2 wall anchors, 2 washers 3/16’’ ID x 3/4’’ OD

Included in parts bag, but not to be used (please discard): 2 wire clamps LP16-AP,

2 no. 8 x 3/8’’ zinc-plated screws, 8 no. 8 x 3/8’’ stainless steel screws,

4 stainless steel 10-32 locknuts, 4 washers 3/16’’ ID x 3/4’’ OD

  WARNING

!

When performing installation, servicing or cleaning the unit, it is recommended to 
wear safety glasses and gloves.

BROAN - EPD61 SERIES - RANGE HOODS 

INSTALLATION GUIDE

Отзывы: