Sentinel

 

Kinetic 200Z  & 200ZH 
      300ZH 
 

User Instructions 

 

PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT. 

 

 

 

Model     Stock Ref. N°  

200Z 

    448733A 

200ZH      449540A 

300ZH       449536A 

 

 

 

Содержание 448733A

Страница 1: ...HOLDING 449355 D doc 449355 D docCopyright 2009 Vent Axia Limited All rights reserved Sentinel Kinetic 200Z 200ZH 300ZH User Instructions PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT Model Stock...

Страница 2: ...ER MAINTENANCE When fitted to a new build property the supply and exhaust filters should be checked at one month intervals for the first six months Disposal This product should not be disposed of with...

Страница 3: ...ill supply cooler air to your room If the room is cooler than the set indoor temperature i e you need the room heating and the outdoor air is warmer than the actual room temperature i e the outdoor ai...

Страница 4: ...rol Unit Buttons Button Function Press to adjust settings and press to save settings Press to go to the above screen or to increase a parameter value Press and hold for more than 2 seconds for fast sc...

Страница 5: ...Fuse 2 A located on main PCB Rated Power 175W max 180W max Physical Height excluding mounting brackets 200mm 300mm Width 570mm 700mm Length excluding spigots 800mm 890mm Weight 26 5Kg 38 5Kg Spigot d...

Страница 6: ...rsion number for 3 seconds No adjustments are possible on this screen V Language Screen The Language screen displays the language used for the screens It is typically displayed for 5 seconds or longer...

Страница 7: ...er 2 m Normal Airflow 30 Set Clock Mon 12 30 Summer Mode On Indoor Temp 25 C Outdoor Temp 14 C Press for 5 s Purge 120 m 100 Boost Airflow 50 Low Airflow 20 Cooker Hood 100 Operation and Monitoring Ov...

Страница 8: ...wer supply failure Low Airflow Normal Airflow Boost Airflow Screen When the start up screens are finished the Low or Normal screen is displayed showing operating status Low Airflow X or Normal Airflow...

Страница 9: ...t Clock screen simply press the button twice to access the Summer Mode screen If the unit is a summer bypass model the Summer Mode screen enables you to switch the summer bypass control on or off This...

Страница 10: ...W5 v1 Vent Wise Input S W1 v2 Vent Wise Input S W2 v3 Vent Wise Input S W3 ls Switched live LS c1 3 Internal Time switch If running on boost due to pressing the button a device will take over the boos...

Страница 11: ...een The Dryout Mode screen displays the time remaining for the building to dry out The unit runs at maximum flow for 1 week Dryout Mode 168 h Defrost Active Screen The Defrost Active screen displays t...

Страница 12: ...cold house The unit will start up every hour and will run for a short time to measure the temperature of the property When the temperature rises e g the heating system is switched back on the unit wi...

Страница 13: ...filters and cover plates 4 Reset the automatic message press and hold the and buttons for 5 seconds 12 Monthly Maintenance Item Action Fan Filters Interval to suit environment Change the Fan Filters...

Страница 14: ...the mains power supply and remove the Filter access Panels and Filters Undo the securing screws and remove the Cover Stage 2 Loosen the Condensate Pipe Jubilee Clip and remove Pipe from Condensate Tra...

Страница 15: ...Caution Keep the Tray as horizontal as possible as this may contain condensate Stage 5 Remove the two Heat Exchanger fixing Brackets and Heat Recovery Cell Note Take care when removing the Heat Recov...

Страница 16: ...d attention is retained in re applying all fixings to their previous locations Spares The following spares may be ordered from Vent Axia Description Part No 200Z 200ZH Part No 300ZH Filters 2 per pack...

Страница 17: ...off and you must phone the telephone number displayed on the screen for assistance Service Phone 01293nnnnnn The Fault Code screen is displayed alternating with the Service screen when a fault has occ...

Страница 18: ...d Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Intern...

Страница 19: ......

Страница 20: ...of purchase against faulty material or workmanship In the event of any part being found to be defective the product will be repaired or at the Company s option replaced without charge provided that th...