![Vendo SVE DL6 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/vendo/sve-dl6/sve-dl6_programming-manual_4040284026.webp)
Instructions for programming SVE01 Board
functions
24
© SandenVendo Europe SpA
4.10.3.3.1 ~ 00 Temperature Threshold
In this submenu you can set the temperature threshold that is managed by HACCP
parameters.
4.10.3.3.2 ~ 01 Temperature Excess Time
In this submenu you can set after how much time you need activate the inhibition of
the selections managed by the HACCP parameters.
4.10.3.3.3 ~ 02 Maximum Temperature Threshold
In this submenu you can set the maximum threshold temperature managed by
HACCP parameters.
4.10.3.3.4 ~ 03 HACCP Products
This submenu allows to select which columns (selections) must be managed by
HACCP parameters.
00 Product 11 Disabled
...
08 Product 19 Disabled
10 Product 21 Disabled
...
18 Product 29 Disabled
20 Product 31 Disabled
...
28 Product 39 Disabled
30 Product 41 Disabled
...
38 Product 49 Disabled
40 Product 51 Disabled
...
48 Product 59 Disabled
80 All Product
4.10.4 ~ 04 SVE01 Update
It is possible to update the software of SVE01 using a USB key.
Pressing
the word "Continue ?" will appear on the display, press
again to view
the files within the USB stick.
Use the buttons
and
to scroll through the files/folders on the USB key to find
the file "SVE01.bin".
The folders are indicated by a slash "/".
Press the button
to enter a folder or to confirm the file to use for the update.
To return to the previous folder you need to press the button
when the display shows
"/.."
The vending machine to confirm the correct board upgrade will emit a beep for about 4
seconds. In case of failure to update the board will issue 3 beeps in sequence.
4
4
3
2
4
4
11.4 Tecnician Menu
03 Cooling
04 SVE01 Update
05 Payment Setting
11 General Menu
10 Test
11 Technician menu
12 EVA Counters
11.3.3 HACCP Products
00 Product 11 Disabled
01 Product 12 Disabled
02 Product 13 Disabled
The writing changes if
active or not the selection.
(Disabled / Enabled)