![Vendo SVE DL6 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/vendo/sve-dl6/sve-dl6_programming-manual_4040284013.webp)
Instructions for programming SVE01 Board
functions
11
© SandenVendo Europe SpA
2.3 Software application for G-Drink Design Line
2.3.1 Initialization
After connecting the vending machine to the electricity grid and switched on the main
power switch on the transformer box, close the door. The lift and the product withdrawal
system "Bucket" will cause an initialization to check the number of shelves and the position
in which they find themselves. The selections start at the top left with the numbers from 11
to 16 "Model DL6" or from 11 to 19 (Model DL9).
The second shelf will begin with 21, the third with 31 and so on.
The maximum number of shelves is 7, the minimum is 3
2.3.2 Product Loading
Open the door
Pull out drawers one by one and load the products
To be able to easily load the bottom shelf, with the door open, manually open the product
door to move the "bucket" to the right, opening it a second time, will return the bucket to
the left. Once you have loaded the products the "Bucket" will automatically return to its
initial position when the door is closed.
2.3.3 "Flap" Feature
When a product is detected within the "flap", the LEDs light up, and the "flap" opens. If the
product is not removed within 2 minutes the LED turns off and the display shows the
message "remove the product." When the product is picked up, the lights flash, and then
the "flap" closes.
2.3.4 Sold-Out Feature
The magnetic sensor included in the product door allows the detection of the product
falling within the "flap", if a selection is made empty, the door will not open and the flap is
closed. The vending machine will put the selection in sold-out, until the door is not opened.
2.3.5 Graphic display
During standby, and in normal sales conditions, on the display of the distributor, will pass
a welcome message, instead during a selection the introduced credit and the number of
selection will appear. When the product is found in the "Flap", the display will scroll the
message "remove the product."
2.3.6 Door switch
For safety reasons 2 door switches have been installed on the machine, 1 for the main
board and for the control board of the slave elevator and 1 for the cooling system. If the
switches do not work or are defective, the cooling system will not start and / or the
machine does not work.
2.3.7 Sales Conditions
The conditions are:
The door switches are activated
The product door is closed
The "Flap" is closed
The initialization of the machine was made correctly
No error was reported
The communication works correctly in MDB