ENGLISH

Please read and save these instructions for future reference. 

Read carefully before attempting to assemble, install, operate or maintain the product 
described. Protect yourself and others by observing all safety information. Failure to 
comply with instructions could result in personal injury and/or property damage! 

®

E33599

SUSPENSION-MOUNT KIT  

Form 472913

Designed to mount VENCO PRODUCTS Industrial Air Circulators (sizes 18" through 48") to ceiling beams or rafters. Allows easy tilt adjustment for 
multidirectional airfl ow. UL/cUL Listed Standard 507.

472913 • Suspension-Mount Kit, Rev. 1, February 2010 

Copyright 2010 © VENCO PRODUCTS • www.vencoproducts.com

GENERAL SAFETY 

WARNING:

  To reduce the risk of fi re, electrical shock, or injury to persons, observe the following: 

a.  Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b.  Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting the means to prevent power from being switched on 

accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Do 
not depend on any switch to disconnect power supply. Always unplug the power cord or turn off and lock disconnecting means as described.

WARNING:

  To reduce the risk of electric shock, do not expose to water or rain.

1.  Read and follow all instructions and cautionary markings.

2.  Disconnect all power before installing or servicing. 

3.  Follow all local safety codes in the United States and Canada, as well as the Occupational Safety and Health Act (OSHA) in the United States.

UNPACKING 

1.  Inspect for any damage that may have occurred during transit.

2.  Shipping damage claim must be fi led with carrier.

3.  Check all parts listed are accounted for. 

MAINTENANCE 

CAUTION: 

 To reduce the risk of injury disconnect from power supply before servicing. Always unplug the power cord.

1.  Depending on the usage and severity, a regularly scheduled inspection should be established.

2.  Check for unusual noises when circulator is running.

3.  Periodically inspect and tighten all bolts, screws and set screws. 

ASSEMBLY AND INSTALLATION 

WARNING:

  Installation and troubleshooting to be performed only by qualifi ed person(s).

CAUTION:

  Support fan securely during assembly and installation.  

1.  Position fan with cord wrap and switch located on top. 

2.  Tighten two whiz nuts(A) on to one U-bolt(B). 

3.  Attach one U-bolt to one swivel bracket(C) and tighten using two nylock nuts(D). 

4.  Using holes provided and four whiz bolts(E), fasten one swivel bracket assembly to the air circulator tube. 

5.  Place one quick link(F) to the fastened swivel bracket and connect with one 6 foot chain(G). 

6.  Repeat steps 1 through 4 for second swivel bracket assembly. 

7.  On the bottom backside of the air circulator tube insert the S-Hook(H) in the hole provided. Attach one 6 foot chain to the opposite side of the S-Hook and 

crimp both sides of S-Hook tight.

8.  Mount air circulator to a structurally adequate ceiling beam or rafter. Using the remaining two threaded chain connectors, secure both swivel bracket assembly 

chains to desired height.  

9.  Align air circulator housing in the desired position for airfl ow and fasten remaining chain to ceiling (fastener by others).

B

Air Circulator Tube

E

D

F

A

C

H

G

Figure 1 — Suspension-Mount Assembly

DIMENSIONS AND SPECIFICATIONS

Model

Use on Model

Includes

Quantity

MAC-SM

MAC-18-339-B4-J1 
MAC-20-327-B4-J1 
MAC-24-323-B3-J1 
MAC-30-324-C5-J1 
MAC-36-322-C5-J1 
MAC-42-320-C7-J1
MAC-48-316-C7-J1

MAC-36-5-J1 
MAC-42-7-J1 
MAC-48-7-J1

(A) 5/16" Whiz Nut
(B) 5/16"-18 U-Bolt
(C) Swivel Bracket
(D) 5/16" Nylock Nut
(E) 1/4"-20 Whiz Bolt
(F) Quick Link
(G) 6' Chain
(H) S-Hook

4
2
2
4
8
4
3
1

472913_Sus-MtKit R1_EN-ES.indd   1

7/27/10   1:21 PM