VEMCO - VR2AR / VR2AR-X Manual
15 March 2019
5
Getting Started
After the VR2AR has been removed from the packaging and inspected for any damage that may have
occurred during shipping, power and test the unit to ensure you can communicate with the receiver and it is
working properly. The VR2AR was shipped with the batteries
installed but NOT connected.
2.1
Connect Battery
VR2AR is shipped with the
battery installed but
NOT
connected
.
Open the VR2AR case as described in
section
. You’ll find two batteries in
the Metal Internal Casing. The smaller
battery operates the release motor and is
already connected. The D or DD-cell
Lithium battery powers all other
operations in the VR2AR and is usually
shipped unconnected within the receiver.
STEP 1
Position the receiver so you can
see the Status Light.
Connect the two battery connector
halves together until a “click” is
heard and the VR2AR
receiver
’s light begins flashing.
Watch for a long green light to indicate the self-tests
were successful. If you see the long red light followed
by more flashes, then contact VEMCO for instructions.
STEP 2
Close the receiver case by following the instructions in section 4
STEP 3
WARNING
Do not over-tighten the case
pieces together or they may
be damaged.