Introduction 

 

To all residents of the European Union 

Important environmental information about this product 

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm 
the environment. 
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialised 

company for recycling. 
This device should be returned to your distributor or to a local recycling service. 
Respect the local environmental rules. 

If in doubt, contact your local waste disposal authorities. 

 
Thank you for buying the 

PS1502A

! Please read the manual thoroughly before bringing this device into service. If the 

device was damaged in transit, don't install or use it and contact your dealer. 
 
The 

PS1502A

 is an adjustable DC-regulated power supply. This user-friendly device is ideal for industrial 

applications. 
 

2. Technical Specifications 

 
Input Voltage 

:  220V/50Hz 

Output Voltage 

:  0-15V continuously adjustable 

Output Current 

:  2A 

Ripple Voltage 

:  < 5mV 

Load Regulation 

:  < 1% + 50mV 

Accuracy (voltmeter and amperemeter) 

:  Class 3 

Protection 

:  current-limiting 

Operating Temperature 

:  0 - 40°C 

Autonomy 

:  8hrs of continuous operation 

Dimensions 

:  155 x 105 x 230mm 

Weight 

:  2.7kg 

 

3. Description of the Front Panel 

 
1.  Voltmeter 
2.  Amperemeter 
3.  Black binding post = negative (-) output terminal 
4.  Red binding post = positive (+) output terminal  
5.  Voltage adjustment  
6.  Power switch 
 

4. Safety Prescriptions 

 

 

Do not connect devices with an electric current requirement > 2A. The max. current will be limited in case of 
prolonged use at 0-8V in order to protect the power transformer. 

 

Install the device in a dry and well-ventilated environment. 

 

Do not try to open the housing yourself. All repairs should be executed by a qualified technician. 

 

Proceed as follows in case of a blown fuse: disconnect the load, replace the fuse with an identical one and locate 
the problem. Next you can reconnect the load. 

 

Содержание PS1502A

Страница 1: ... device is ideal for industrial applications 2 Technical Specifications Input Voltage 220V 50Hz Output Voltage 0 15V continuously adjustable Output Current 2A Ripple Voltage 5mV Load Regulation 1 50mV Accuracy voltmeter and amperemeter Class 3 Protection current limiting Operating Temperature 0 40 C Autonomy 8hrs of continuous operation Dimensions 155 x 105 x 230mm Weight 2 7kg 3 Description of th...

Страница 2: ... verwijdering Dank u voor uw aankoop Lees deze handleiding grondig voor u het toestel in gebruik neemt Werd het toestel beschadigd tijdens het transport installeer het dan niet en raadpleeg uw dealer De PS1502A is een regelbare DC gestuurde voeding Dit gebruikersvriendelijk toestel is uitstekend geschikt voor industriële toepassingen 2 Technische specificaties Ingangsspanning 220V 50Hz Uitgangsspa...

Страница 3: ...nnement Ne jetez pas cet appareil et des piles éventuelles parmi les déchets ménagers il doit arriver chez une firme spécialisée pour recyclage Vous êtes tenu à porter cet appareil à votre revendeur ou un point de recyclage local Respectez la législation environnementale locale Si vous avez des questions contactez les autorités locales pour élimination Nous vous remercions de votre achat Lisez att...

Страница 4: ... dem Produkt oder der Verpackung zeigt an dass die Entsorgung dieses Produktes nach seinem Lebenszyklus der Umwelt Schaden zufügen kann Entsorgen Sie die Einheit oder verwendeten Batterien nicht als unsortiertes Hausmüll die Einheit oder verwendeten Batterien müssen von einer spezialisierten Firma zwecks Recycling entsorgt werden Diese Einheit muss an den Händler oder ein örtliches Recycling Unter...

Страница 5: ...n Schließen Sie keine Geräte mit einem Strombedarf von mehr als 2A an Bei langfristigem Gebrauch zwischen 0 8V wird der max Strom begrenzt um den Netztrafo zu schützen Installieren Sie das Gerät in einem trockenen und einem gut gelüfteten Raum Versuchen Sie nie selber das Gehäuse zu öffnen Lassen Sie das PS1502A von qualifizierten Fachleuten reparieren Machen Sie Folgendes wenn die Sicherung durch...

Страница 6: ...PS1502A VELLEMAN 6 WIRING DIAGRAM BEDRADINGSSCHEMA CÂBLAGE VERKABELUNG ...

Отзывы: