User manual 

CALIBRATING THE TESTER 

Before you can start testing components, you will have to calibrate the tester. What you'll 
need is a capacitor with a capacity between 100nF and 20µF.  
Then follow the calibration procedure below:  

1. Connect the 3 probes together. 

2. Press the button on the tester and immediately press it again if you see "Selftest mode" 
on the screen. If successful, you should see "R0=". 

3. When you "isolate Probes" appears on the screen, disconnect all the probes. 

4. When you see “1 -||-3 > 100nF” appear on the screen, connect the capacitor to probes 1 
and 3. 

5. After a while, the calibration should end with success. 

  

CONNECTING A COMPONENT 

Connecting a component is easy; simply connect the leads of a component to the 
connectors. The order/polarity doesn't matter because the tester will figure this out on its 
own.   
When testing a component, make sure that you do not touch the component during the test 
and that it is placed on a non-conductive pad.   

EXTRA FEATURES 

You can access the extra features by long pressing the button to enter the menu.   
 

f-Generator 

   

By using the additional "f-Generator" (frequency generator) function, the selectable 
frequencies can be 
switched with key presses. With a long key press (> 0.8s) you will stop the frequency 
generator and 
return to the function menu.   
 

10-bit PWM 

   

The additional "10-bit PWM" (Pulse Width Modulation) function generates a fixed 
frequency with 
selectable pulse width at the pin TP2. With a short key press (< 0.5s) the pulse width is 
increased by 1%, with a longer key press the pulse width is increased by 10%. If 99%   
is overstepped, 100% is subtracted from the result. You can exit this mode with a very long 
key press (> 1.3s).   
 