Velleman HAA2801 Скачать руководство пользователя страница 1

HAA2801

Programming & Installation Manual

FOR ELECTRIC LOCK, INTER-LOCK

AND SECURITY SYSTEM INSTALLATIONS

SPLIT-DECODED CONTROLLER

FOR HAA28XX SERIES SECURITY KEYPADS

VERSION: 11/2012

Содержание HAA2801

Страница 1: ...HAA2801 Programming Installation Manual FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM INSTALLATIONS SPLIT DECODED CONTROLLER FOR HAA28XX SERIES SECURITY KEYPADS VERSION 11 2012 ...

Страница 2: ...TS FOR THE AUXILIARY TERMINALS PROGRAMMING FOR FULL FEATURES Supplementary Information Set System in Programming Mode with The Master Code Direct Access to Programming Mode with The DAP Code 8 0 8 0 Refresh The System with The Refreshing Code 9 9 9 9 The Default Values of The Keypad FEATURE PROGRAMMING KEY IN AND STORE THE DESIRED VALUES Programming Criteria for Codes Record A Master Code Record A...

Страница 3: ...Button An Unique Feature of A Contemporary Keypad Where And Why Going Out Needs Attention Egress Delay Warning And Alarm Configurations of The Egress Warning And Alarm Door Opening Alarm Timer Close The Programming Mode The Operation Modes and The Wiegand Output Wiegand Output at Keypad Operation Mode PROGRAMMING SUMMARY CHART Supplementary Information 3 4 3 4 3 4 3 5 3 5 3 5 3 6 3 6 3 7 3 7 3 8 3...

Страница 4: ... Cards The slave keypads take the features and the functions programmed in the master keypad to operate the system The decoder interprets the data and operates the desired functions faithfully For more info concerning this product and the latest version of this manual please visit our website www velleman eu The information in this manual is subject to change without prior notice FEATURES HAA2800 ...

Страница 5: ...N O dry contacts 5A 24VDC Max Output Relay 2 N C N O dry contacts 1A 24VDC Max Output Relay 3 N C N O dry contacts 1A 24VDC Max Dimensions 32 5 H X 120 W X 87 D mm Plastic Box Weight 250g net RF Remote Controller HAA2800 Only Number of Self leaning Codes Over 1 Million Number of RF Control Keys 40 Maximum 4 Control Channels Output 1 2 3 Door Chime Operation Frequency 433MHz Control Distance 60 Met...

Страница 6: ...nt setting change is required for Split decoded operation with the ex factory settings 6 LINK UP JUMPER OFF ON OFF CODE LEARNING BUTTON HAA2800 ONLY REMOTE CONTROL SIGNAL STATUS HAA2800 ONLY INTERNAL SIREN DOOR CHIME CONNECTION TERMINALS MAINS OUTPUT BEEP JUMPER ON OR OFF FUNCTION MODE JUMPER 1 SPLIT DECODED 2 STAND ALONE MODE 1 3 STAND ALONE MODE 2 ADJUSTABLE TIMER FOR OUTPUT 1 TURN CLOCKWISE FOR...

Страница 7: ...is also important i Do not apply power to the system while it is in installation ii Check carefully all the wirings are correct before applying power to the system for testing SPLIT DECODED MODE for HAA2800 HAA2801 Split decoded Mode needs at least one keypad to work with the decoder The decoder decodes all the commands from the keypad to operate its outputs It is an unique solution to immediately...

Страница 8: ...mmon Ground Terminal 2 or 11 to the ground of the keypad unit to make up the return path for the data and the power source Make all other installation connections to the decoder unit but not to the keypad unit in Split Decoded Mode The system provides full feature from the decoder unit according to the functions programmed in the keypad The Function Jumper of the HAA2800 has been put on Position 1...

Страница 9: ...ree Output Relays are controlled by the RF Remote Key with the following functions Output 1 Start Stop Output 2 Start Stop Output 3 Manual Momentary POSITION 3 STAND ALONE MODE 2 ADJUSTABLE TIMER FOR OUTPUT 1 MAINS LED LAMP ON Position 3 is one of the settings for Stand Alone mode All the three Output Relays are controlled by the RF Remote Key with the following functions Output 1 Adjustable Timer...

Страница 10: ...ing function for small power but it is usually good enough for controlling of an alarm system The maximum rating is 24V DC 100mA Sink OPEN COLLECTOR OUTPUT Output switches to ground when activated N O CONTACT OUTPUT Output switches to ground when activated EQUIVALENT ALARM O P KEY ACT O P N O COM N C N O COM N C N O COM N C TAMPER GND DOOR SENS O P 1 INHIB INT LOCK DU OUT DOOR BELL IN EG IN DATA I...

Страница 11: ...oded Mode Only An NPN transistor open collector output with the maximum power rating of 24VDC 100mA sink It is equivalent to an N O Normally Open terminal switching to ground after the entry of Duress Code Use it to trigger an alarm zone of a security system or turn on a buzzer to notify a guard Please see the application hints for more information Duress Function is available only on Split decode...

Страница 12: ...o terminal 2 12 TAMPER IN Tamper Switch Normally Closed Input Terminal A Normally Closed N C input terminal referring to ground It is prepared for the tamper switch of the keypad connecting to it When the tamper switch is open circuit it triggers the internal siren and the Alarm Output terminal Link up this terminal to Ground with jumper if not used The alarm lasts for 3 minute in stand alone mode...

Страница 13: ... N O Normally Open terminal referring to ground It switches to ground for 10 seconds on each key touch on the keypad or receiving of a command signal from the RF remote key It can be used to drive a small power device such as a relay or a low power control point of other equipment See the Application Hints for more information 23 ALARM O P Alarm Output An NPN transistor open collector output with ...

Страница 14: ...ogramming Location 90 b The alarm activates during the Egress Delay period and it stops at the expiry of the Egress Delay c Alarm Output and Internal Siren activate 3 Egress Delay Warning a The Egress Delay Warning is enabled by programming from keypad at Programming Location 90 b The warning activates during the Egress Delay period and it stops at the expiry of the Egress Delay c The warning beep...

Страница 15: ...2 1 Press button A to operate Output 1 2 Press button B to operate Output 2 3 Press button C to operate Output 3 4 Press button D to operate the built in Door Chime STAND ALONE MODE HAA2800 ONLY The system that operates in Stand Alone mode does not require the keypad It is directly controlled by the RF Remote Key for the outputs It is an ideal solution for the remote controls of door strike alarm ...

Страница 16: ...connect DOOR SENSOR terminal to ground if not used Always connect TAMPER terminal to ground if not used Make 3 wire Connection DATA I O to the keypad in the HAA28xx Series More than one keypads can be connected in parallel ALARM O P KEY ACT O P N O COM N C N O COM N C N O COM N C TAMPER GND DOOR SENS O P 1 INHIB INT LOCK DU OUT DOOR BELL IN EG IN DATA I O KEYPAD PWR GND 12 24V DC N O ELECTRIC LOCK...

Страница 17: ...see the NOTE stated in the Application Example 1 ALARM O P KEY ACT O P N O COM N C N O COM N C N O COM N C TAMPER GND DOOR SENS O P 1 INHIB INT LOCK DU OUT DOOR BELL IN EG IN DATA I O KEYPAD PWR GND 12 24V DC N O ELECTRIC LOCK 1N4004 DOOR 1 OUTPUT RELAY 1 N O Output for Fail secure Lock N C Output for Fail safe Lock N C OUTPUT 1 OUTPUT 2 OUTPUT 3 DIGITAL KEYPAD AD 1312 OR AP 960 EGRESS BUTTON DOOR...

Страница 18: ...n the pre set delay time Enable the function at Location 81 Inter lock Control When the door is open the interlock output of the keypad will give a command to stop the other keypad in an inter lock system Door Opening Alarm Door Opening Alarm is designed for the emergency door only It is always given when the door is opened unless a valid user code or card is used prior to the door is opened Enabl...

Страница 19: ...LED lamp and or a small buzzer to notify a guard or to energize a relay to switch ON lights or trigger an CCTV Camera to start recording Make sure that the relay for switching ON lights has high enough isolation between high voltage and low voltage to prevent damage of the keypad Only one connection option is recommended Make sure the sink current does not exceed the maximum rating of 100mA Extern...

Страница 20: ...disarm control of an alarm system Consult your alarm control panel manual for the appropriate output contact to be used in arm disarm control Usually set output 2 to Momentary mode Programming Option 521 Location 52 Output Mode 1 for multi station systems and Start Stop mode Programming Option 520 Location 52 Output Mode 0 for single station systems F OUTPUT 2 OR OUTPUT 3 i Shunting an N C Zone ii...

Страница 21: ...ly and they can be repeated use in the other keypad s in the system REMARK The feature of reading EM Cards only available on the keypads with EM Card reader No keypad is supplied with the Access Controller User has to purchase the keypad seperately Only the keypads with DATA I O port are compatible with the Access Controller SET SYSTEM INTO PROGRAMMING MODE WITH THE MASTER CODE IMPORTANT NOTE 1 2 ...

Страница 22: ...N terminal of the keypad to GND to simulate of pressing the Egress Button in order to enable the DAP function 3 This procedure is required for both Master keypad and Slave keypad in Split decoded operation with DAP Code going into programming mode Switch OFF all the power for 1 minute to ensure that the system is fully discharged Switch ON power again The system is in Power up Mode for 1 minute an...

Страница 23: ...2 Nil User Program Required 3 0 User PINs Cards for O P 3 Nil User Program Required 4 0 Visitor Codes Nil User Program Required 4 1 Duress Code for O P 1 Nil User Program Required 4 2 Duress Code for O P 2 Nil User Program Required 4 3 Duress Code for O P 3 Nil User Program Required 5 1 O P Mode of The O P 1 Time 5 Sec Momentary 5 2 O P Mode of The O P 2 Time 5 Sec Momentary 5 3 O P Mode of The O ...

Страница 24: ...ode for Secondary User PIN or vice versa e Getting Advantages from The Secondary User PINs The repeated Secondary PINs can be used as a Group Common User Code or called Department User Code for a group of EM Cards which simplifies the programming of using large number of different User PINs EM Card with Department Code prevents a lost card used by people of other department Also it will be easier ...

Страница 25: ...e Keypads are required to set with the same Master Code Example Set a Master Code with the number of 2 2 3 3 RECORD A SUPER USER PIN Location 02 The Super User PIN has TWO functions It is prepared for the owner to simply use only one User PIN to operate the three outputs of the keypad and make operation inhibit enable disable to the system outputs SUPER USER PIN The Super User PIN can be 4 to 8 di...

Страница 26: ...PIN does not govern the Egress Button The door still can be opened with it from inside The Super User PINs are always valid They are not governed by any inhibit or lock out function in the system RECORD THE COMMON USER PINS FOR OUTPUT 1 2 3 Locations 03 04 05 The Common User PINs 1 2 and 3 are prepared for operating of the Output 1 Output 2 and Output 3 respectively as an enhance code The Common U...

Страница 27: ...e the programming example below for the details USER ID NUMBER A 3 digit ID is an identified number for each User PIN and or Card Repeated ID number will be rejected by the system a ID Number 000 999 for 1 000 User PINs Cards to operate Output 1 b ID Number 001 100 for 100 User PINs Cards to operate Output 2 c ID Number 001 100 for 100 User PINs Cards to operate Output 3 CARD OR USER PINS The User...

Страница 28: ...y ii Operation while the system is back to operation mode 1234 a b a Key in the Private User PIN 1 2 3 4 b Confirm it with the key Output 2 activates 3 Example 3 EM Card Secondary User PIN i Programming 10 3 002 24680 a b c d e f a The card is programmed for operating of the Output 1 b The operation is EM Card Secondary User PIN c Take the ID number 002 in Group 1 to store the Card PIN which is on...

Страница 29: ... Press to store the Card into memory Two beep confirms a valid entry Put the EM card close to the reader One beep confirms the reading and 30 seconds waiting time is given for the entry of the Common User PIN the Amber LED keeps flashing Key in the Common User PIN 1 3 5 7 the number programmed in Location 0 3 for Output 1 in the previous Example Confirm it with the key Output 1 activates Key in th...

Страница 30: ...S When a new Visitor Code is put in the same Code box the old code is replaced The Visitor Codes can be 4 8 digits for the Manual Mode code entry The Visitor Codes MUST be in the same digit length with the Master Code for Auto Mode code entry The Visitor Codes can not reset Duress Output NOTE All Visitor Codes will be cleared after power down to prevent extension confusion of their valid time limi...

Страница 31: ... The Output 1 ID 01 10 10 Duress Codes Are Allowed for The Output 2 ID 01 10 10 Duress Codes Are Allowed for The Output 3 0999 Clear all the Duress Codes from the selected Location group Please see the programming example below for the details THE DURESS CODES 50 10 and 10 Duress Codes can be programmed for Output 1 2 and 3 respectively They are stored in their two digit Code ID box When a new Cod...

Страница 32: ...unction 3369 Duress Output activates switches to ground Output 1 activates Key in The Duress Code 3 3 6 9 in Group 1 for Output 1 Again 3369 Duress Output keeps activating and no change in its state keeps to ground Output 1 activates again Key in A Normal User PIN 1 3 6 9 in Group 1 for Output 1 1369 Duress Output resets back to OFF state but has no function on Output 1 Report Duress in EM Card Op...

Страница 33: ...e Super User Code that operates the desired output before the end of the time Example Reset Output 1 1 Output 1 resets Reset Output 2 2 Output 2 resets Reset Output 3 3 Output 3 resets PERSONAL SAFETY AND SYSTEM LOCK OUT Location 60 SAFETY LOCK OUT OPTIONS The Options are represented by their Mode Numbers in programming They are described below 1 After 10 successive false Card User Code trials the...

Страница 34: ... beep and the Unsuccessful User Code Card entry 5 beeps NOTE The beeps for the Warning and the Power up Delay do not belong to pacifier tones and can not be set to OFF 1 Pacifier Tone ON Default All the Pacifier Tones available from the keypad are enabled They are the response tones indicating the operation status of the keypad after the Card User Code is entered 0 Pacifier Tone OFF All the Pacifi...

Страница 35: ... door forced open warning beeps and activates the alarm output Terminal 13 instantly if the door is forced to open without a valid User PIN Card or pressing of the Egress Button The beeps and alarm will last as long as the time set on the timer and it can be stopped at anytime with an User PIN Card in Group 1 before the end of the time The Manner of The Door Forced Open Warning a The door is force...

Страница 36: ...s pressed Further setting of the egress button with holding contact for the delay even gives higher level of security to a controlled door Kindergarten Young children are always active Some of them may be willing to go out to explore their ways of playing For safety reason teachers have to watch all of them in the attended area Leaving school alone without the companion of parents or teacher is da...

Страница 37: ...e Button The system gives Warning Beeps during Egress Delay Good for the place required attention The keypad beeps while the button is kept pressed during the people are waiting for the door open 6 Holding Contact Mode with Warning Beep Alarm Press and hold the Button The system gives Warning Beeps and also activates its Alarm O P during Egress Delay This is usually an Emergency Exit The door can ...

Страница 38: ...into the box to enable the function of the Door Opening Alarm The figure is the time in second of the alarm duration which starts to count after the door is opened and it resets automatically when the time reaches The alarm can be stopped with the User Codes Cards or the Super User PIN for Output 1 at any time before the end of the alarm time NOTE The Door Opening Alarm is designed to protect the ...

Страница 39: ...Split Decoded Mode The Only Mode will Send Out the Link up Code The keypad unit provides the Wiegand Data Output for the valid user PINs Codes and Cards exactly like in the Stand Alone Mode The Master keypad will transfer all the programmed feature data except the user PINs Codes and Cards data to the Access Controller decoder right after it exits the programming mode A Split decoded keypad system...

Страница 40: ...VALID PERIOD 00 One Time 01 99 Hours CODE 3 VISITOR CODE 4 8 Digits 40 CODE1 CODE2 CODE3 NIL 4 1 Duress Code for O P 1 CODE ID O P 1 01 50 CODE ID O P 2 01 10 CODE ID O P 3 01 10 DURESS CODE 4 8 Digits 41 CODE ID DURESS CODE NIL 4 2 Duress Code for O P 2 42 CODE ID DURESS CODE NIL 4 3 Duress Code for O P 3 43 CODE ID DURESS CODE NIL 5 1 O P Mode for O P 1 OUTPUT MODE TIME 0 Start Stop 1 99999 Seco...

Страница 41: ...s Cards only 94 WIEGAND O P MODE Mode 0 Keypad Mode SYSTEM CODES FUNCTION CODE ENTRY RESULTS 0 0 0 0 Factory Set Master Code for User to set system in programming Mode at the first time THIS IS NOT A PERMANENT SYSTEM CODE IT IS CHANGED IF A NEW MASTER CODE IS PROGRAMMED 0000 OR NEW MASTER CODE System in Programming Mode 9 9 9 9 REFRESH CODE Refresh the system and set all its function back to defau...

Страница 42: ...uits répondent à des exigences de qualité rigoureuses et à des dispositions légales en vigueur dans l UE Afin de garantir la qualité nous soumettons régulièrement nos produits à des contrôles de qualité supplémentaires tant par notre propre service qualité que par un service qualité externe Dans le cas improbable d un défaut malgré toutes les précautions il est possible d invoquer notre garantie v...

Отзывы: