background image

LIGHT COMPUTER

 

K5201

 

ILLUSTRATED ASSEMBLY MANUAL 

 

H5201IP-1 

Total solder points: 240  
Difficulty level: 

beginner

 1   2   3    4  5 

advanced

 

16 differe

nt pattern

s and 7 o

utputs 

provide a

 unique li

ght show

Содержание K5201

Страница 1: ...LIGHT COMPUTER K5201 ILLUSTRATED ASSEMBLY MANUAL H5201IP 1 Total solder points 240 Difficulty level beginner 1 2 3 4 5 advanced 16 different patterns and 7 outputs provide a unique light show...

Страница 2: ...ed External oscillator input Daisy chain units to create even bigger light shows Special setting for two linked units to create 14 channel operation 7 LED pattern indication Specifications Power suppl...

Страница 3: ...he eyes Needle nose pliers for bending leads or to hold components in place Small blade and Phillips screwdrivers A basic range is fine For some projects a basic multi meter is required or might be ha...

Страница 4: ...the solder joints are cone shaped and shiny 3 Trim excess leads as close as possible to the solder joint REMOVE THEM FROM THE TAPE ONE AT A TIME AXIAL COMPONENTS ARE TAPED IN THE CORRECT MOUNTING SEQ...

Страница 5: ...0 1 B R17 100 1 0 1 B R18 100 1 0 1 B R19 100 1 0 1 B R20 100 1 0 1 B R21 100 1 0 1 B 3 1 4W Resistors R C1 10nF 103 C2 100nF 104 C3 100nF 104 C4 100nF 104 5 Capacitors IC1 8p IC2 14p IC3 28p 4 IC soc...

Страница 6: ...6 LD7 L1 L2 L3 L4 L5 L6 L7 N SIG IN OSC OUT J1 X2 RST T1 BC547 T2 BC547 T3 BC547 T4 BC547 T5 BC547 T6 BC547 T7 BC547 8 Transistors C5 1 F C6 1 F C7 1000 F 9 Electrolytic Capacitors Watch the polarity...

Страница 7: ...3 The 12 position rotary switch SW3 must be configured for 8 positions Turn the switch all the way counterclockwise Remove the nut and the lock washer Lift the stop washer and move it to position 8 Pu...

Страница 8: ...with resistive loads such as regular incandescent light bulbs The unit is not suitable for use with transformer operated lighting or fluorescent lighting 17 ASSEMBLY HOOK UP AND USE Assembly Hook up...

Страница 9: ...by means of a wire jumper A external 5V CMOS clock signal e g generated by a beat detector can be connected between GND and SIG IN Assembly Hook up Use L7 L6 L5 L4 L3 L2 L1 10A FUSE 50mA FUSE N L N MA...

Страница 10: ...rtant that each unit gets its own power supply transformer Assembly Hook up Use L4 L3 L2 L1 20A FUSE 50mA FUSE N L N MAINS SLOW 7 5 9VAC 0 25A 7 5 9V SIG IN RST OSC OUT RESET BANK SELECT PROGRAM SELEC...

Страница 11: ...use fuses rated as indicated Patterns 15 and 16 have been developed for cascade use Choose pattern 15 for the master unit and pattern 16 for the slave unit Use Choose between 8 different patterns with...

Страница 12: ...f the casing so that all controls are accessible and the LED s are visible Make holes in the front panel as shown in figure 3 0 Mount the PCB on the front panel with help of the included bushes and bo...

Страница 13: ...13 All values are in mm 1mm 0 04 Finishing FIG 3 0...

Страница 14: ...14 19 Schematic diagram Schematic diagram...

Страница 15: ...15 PCB 20 PCB...

Страница 16: ...ions and typographical errors reserved Velleman Components nv H5201IP 2004 ED1 VELLEMAN Components NV Legen Heirweg 33 9890 Gavere Belgium Europe www velleman be www velleman kit com 5 4 1 0 3 2 9 2 8...

Отзывы: