background image

10/18

Manual installation Veko Sensor

Manual Veko linear lighting system / V20 / 2021-02

1

4

7

9

2

5

8

3

6

MD-L-R

- Length -

- Width -

MD-L-N

This page applies to all MD-L subtypes and config-
urations.
1 Switch off the power supply before connecting the 
   light system.
2 Example of a sensor. Note: Sensor type
   and/or linear lighting profile may vary.
3 Ensure correct position of poles and wiring.

   Plug the connector into the flat cable.
5 Press and attach the safety clip for 
   emergencies in the continuous-row 
   lighting profile.
6 Install the sensor in the profile.
7 In the case of the Narrow lens, a cover  
   can be used to limit the range of the

  sensor, if necessary. This cover can be cut to size  

   with pliers or scissors on the break line to achieve 
   the desired range and angle of the sensor.
8 Technical data.
9 Sensor range:

MD-L-R (round lens)

 

MD-L-N (narrow lens)

Technical data

Power (W) 
Voltage (V)
Length (mm) 
Frequency (Hz) 
Circuit 
Sensitivity settings 

Twilight circuit 

Switch-off delay relay
Environment application 
Corridor function / dynamic switch 

(example: 10-100 %)
Programming 

ENEC certification 
Warranty

1,5 W < 4 W (Switched off- < on)
220-240 V
300 mm
50 ÷ 60 Hz
6 A
5 (standard max. sensitivity)

Adjustable in 9 steps 0-1.000 Lux

Relay 0-99 minutes
-25 °C - + 35 °C
In combination with DALI driver 

and control gear
Readout and re-programmable by 

colour coding with LED in sensor
In application at DEKRA
5 years