SD500 Spindle Servo Drive Manual
66
F11.27
(0x0B1B)
Fault
display
selection
V/F SVC FVC PMVF PMSVC PMFVC
Ones-bit: set whether to display the faults when the they are
self-recovered
0: no display
1: display
0x0001
(0x0000~0x0001)
RUN
Table 4-40
4.12 Group F12: Communication Parameters
Group F12.0x: MODBUS slave parameters
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F12.00
(0x0C00)
Master/Slave
selection
V/F SVC FVC PMVF PMSVC PMFVC
0: slave, 1: master
0
(0~1)
STOP
F12.01
(0x0C01)
Modbus
communication
address
V/F SVC FVC PMVF PMSVC PMFVC
Different values are set for different slaves.
1
(1~247)
STOP
F12.02
(0x0C02)
Communication baud
rate
V/F SVC FVC PMVF PMSVC PMFVC
0:1200 bps
1:2400 bps
2:4800 bps
3:9600 bps
4:19200 bps
5:38400 bps
6:57600 bps
3
(0~6)
STOP
F12.03
(0x0C03)
Modbus data format
V/F SVC FVC PMVF PMSVC PMFVC
0:(N, 8, 1) No checksum.
Data bit:8.
Stop bit:1
1:(E, 8, 1) even parity.
Data bit:8.
Stop bit:1
2:(O, 8, 1) odd parity.
Data bit:8.
Stop bit:1
3:(N, 8, 2) No parity.
0
(0~5)
STOP