44
AC310 Universal AC Drive Service Manual
Common Mode Inductors
L1=WCM-453228-510YT01
(
Maximum permissible current
230mA
)
TSS Tube
D4/D5=WES806S
,
Breakdown voltage: 6.67~7.37V
Resistances
R39/R41=5.6K/0805
,
R42/R43=10K/0402
,
R92/R179=62Ω
R46/R47/R48=4.7K
Capacitors
C14/C15=1NF/0402
,
C19=100NF/0402
,
C24=2.2UF/10V
3.6 Drive Signal Processing Circuit
1. Circuit Description: