AC310 Universal AC Drive Service Manual
14
2.3 Current Detection Circuit
1. Circuit composition
ACS720 current chip is used for sampling, the chip outputs 1.5V bias voltage with zero
current and provides a 1.5V REF. The sampling signal is calculated by the operational
amplifier and sent to the control board.
In addition, the internal circuit of the chip detects a delay of 4us, which is a large delay
for the overcurrent protection function, so the internal overcurrent protection function is
introduced.
The ACS720 has a user-configurable double-fault function, with fast and slow fault
outputs for short-circuit and overcurrent fault detection. Using the fast protection pins
VOC_F and FAULT_F/, the device sends out a low FAULT signal within 1.5us when the
Содержание AC310
Страница 23: ...22 AC310 Universal AC Drive Service Manual 2 7 Switching Power Supply...
Страница 47: ...46 AC310 Universal AC Drive Service Manual 3 7 Keyboard Circuitry...
Страница 54: ...53 AC310 Universal AC Drive Service Manual 3 10 Current Acquisition Detection and Maintenance...
Страница 55: ...54 AC310 Universal AC Drive Service Manual 3 11 OC Fault Detection and Maintenance...