12
5 Set up with the display and adjustment module
VEGAPULS 66 • Profibus PA
47140-EN-210621
1
2
Fig. 7: Installing the display and adjustment module in the double chamber
housing
1 In the electronics compartment
2 In the connection compartment
Note:
If you intend to retrofit the instrument with a display and adjustment
module for continuous measured value indication, a higher lid with an
inspection glass is required.
5.2 Parameter adjustment
1. Go to the menu "
Setup
" via the display and adjustment module.
2. In the menu item "
Medium
"you select the medium of your ap-
plication, for example "
Aqueous solution
".
3. Select in the menu item "
Application
" the vessel, the application
and the vessel form, for example, storage tank.
4. Carry out the adjustment in the menu items "
Min. adjustment
"
and "
Max. adjustment
".
Set parameters