background image

19

Notes

VEGAPULS 65 • 4 … 20 mA/HART - four-wire

51885-EN-160621

Содержание VEGAPULS 65

Страница 1: ...Quick setup guide Radar sensor for continuous level measurement of liquids VEGAPULS 65 4 20 mA HART four wire Document ID 51885...

Страница 2: ...ection procedure 8 4 2 Wiring plan double chamber housing 9 5 Set up with the display and adjustment module PLICSCOM 5 1 Insert display and adjustment module 10 5 2 Setup steps 11 5 3 Menu schematic 1...

Страница 3: ...plication specific hazards e g vessel overfill or damage to system components through incorrect mounting or adjustment 1 4 General safety instructions This is a high tech instrument requiring the stri...

Страница 4: ...ment NE 43 Signal level for malfunction information from measuring transducers NE 53 Compatibility of field devices and display adjustment components For further information see www namur de 1 8 FCC a...

Страница 5: ...That is why we have introduced an environment management system with the goal of continuously improving company environmental pro tection The environment management system is certified according to DI...

Страница 6: ...With the serial number you can access the delivery data of the instru ment via www vega com VEGA Tools and Instrument search You can find the serial number on the inside of the instrument as well as o...

Страница 7: ...nstructions 1 Distance from the vessel wall 200 mm the antenna should protrude 10 mm into the vessel 500 mm 19 69 Fig 1 Distance of the antenna to the vessel wall vessel ceiling 2 Note min socket diam...

Страница 8: ...sensor through the cable entry 6 Lift the opening levers of the terminals with a screwdriver see following illustration 7 Insert the wire ends into the open terminals according to the wir ing plan Fig...

Страница 9: ...51885 EN 160621 4 2 Wiring plan double chamber housing The following illustrations apply to the non Ex and also to the Ex ia version 4 20 mA PE L N L1 N GND 1 2 1 2 3 4 4 20mA IS Fig 3 Wiring plan do...

Страница 10: ...on the electronics you can choose any one of four different posi tions each displaced by 90 3 Press the display and adjustment module onto the electronics and turn it to the right until it snaps in 4...

Страница 11: ...100 00 1 000 m d 2 000 m d Min adjustment 0 00 5 000 m d 4 000 m d 3 Select in the menu item Medium the medium of your applica tion for example Aqueous solution Medium Liquid 4 Select in the menu item...

Страница 12: ...tances for example 10 and 90 is also possible Starting point for these distance specifications is always the seal surface of the thread or flange The actual product level during this adjustment is not...

Страница 13: ...an adjustment with other distances for example 10 and 90 is also possible Starting point for these distance specifications is always the seal surface of the thread or flange The actual product level d...

Страница 14: ...1 4 not known Damping 1 5 0 s Linearisation curve 1 6 linear Sensor TAG 1 7 Sensor Display Basic adjustment 2 Display Diagnostics Service Info Displayed value 2 1 Scaled Display unit 2 2 Volume l Sca...

Страница 15: ...ode 3 6 mA min current 4 mA max current 20 mA Simulation 4 4 Start simulation Reset 4 6 Select reset Unit of measurement 4 7 m d Language 4 8 Deutsch SIL 4 9 Not activated HART mode 4 10 Standard Addr...

Страница 16: ...supply Electromechanical data version IP 66 IP 67 Cable entry Double chamber housing 1 x cable gland M20 x 1 5 cable 5 9 mm 1 x blind plug M20 x 1 5 plug M12 x 1 for VEGADIS 61 optional or 1 x closin...

Страница 17: ...17 Notes VEGAPULS 65 4 20 mA HART four wire 51885 EN 160621...

Страница 18: ...18 Notes VEGAPULS 65 4 20 mA HART four wire 51885 EN 160621...

Страница 19: ...19 Notes VEGAPULS 65 4 20 mA HART four wire 51885 EN 160621...

Страница 20: ...of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior n...

Отзывы: