background image

 

 
 
 

Model NEO-10 

Version 1.0 

 

 

Technical Manual 

 

November 

26, 

2003 

      PN: 

803968 

 

Содержание NEO-10

Страница 1: ...Model NEO 10 Version 1 0 Technical Manual November 26 2003 PN 803968 ...

Страница 2: ...NAL 5 3 2 GENERAL SETUP VIA WEB PAGES 8 3 3 BASIC ETHERNET SETUP SCREEN 8 3 3 1 Use DHCP Server 8 3 3 2 Unit IP Address 8 3 3 3 Subnet Mask 8 3 3 4 Gateway Address 8 3 3 5 DNS Addresses 1 3 8 3 4 MULTICAST SETUP 10 3 5 DEBOUNCE INPUT SETTINGS 11 3 6 ECHO PACKET 12 3 7 CLONE FROM OTHER NEO 14 3 8 PIN CHANGE 15 3 9 SAVE CHANGES TO EEPROM 16 4 BILL OF MATERIAL AND SCHEMATICS 17 5 WARRANTY SERVICE REP...

Страница 3: ... Version 2 52 of C Soft supports control and monitoring functions to support multiple NEO devices on the network Later releases of software for the desktop VoIP capable consoles will support NEO as well In addition to the I O functions of the device NEO supports 10 channels of echo packet functionality Echo Packet is a method of copying voice data content on the network from and to multicast addre...

Страница 4: ... 2 3 Relay Input Ports There are 10 RJ45 ports that are used to sense inputs and control external events Each connector is connected to a DPDT relay Both sets of poles are brought out to the connector allowing for two separate circuits to be controlled by a single relay Figure 1 shows the pin out of the rear RJ45s Relay1 designates the pins on one half of the DPDT relay and Relay2 the other half T...

Страница 5: ...h as Netscape or Internet Explorer Before connecting to the adaptor with the browser an IP address and Mask that is compatible with the users existing network must be set See your network administrator to determine the proper values Once these values have been set the unit must be reset for them to take affect To change the IP and Mask addresses using a Hyper Terminal program follow these simple s...

Страница 6: ...6 At the main Hyper Terminal screen type uppercase S then enter Enter technobabble for the factory password ...

Страница 7: ...o you want to change E Current Gateway address do you want to change F Do you want to reset any of the above Once all parameters have been entered and saved allow the unit to reset by answering Yes to the final question The unit will reset in 10 20 seconds Startup text will be sent to the serial port allowing verification of the setup parameters having been recorded correctly A B C D E F ...

Страница 8: ...st turned on Since it is important that the NEO always be located in a known location for all consoles utilizing it on the network this should not be used as the normal operating mode It is useful sometimes to determine the settings that might be used for a particular network or testing 3 3 2 Unit IP Address In addition to the method outlined in section 3 1 the base IP address can be changed from ...

Страница 9: ... parameters are set press the Submit button to send them back to the NEO from the web browser The parameters are not updated until they are actually saved to EPROM Section 3 9 Figure 3 Basic Ethernet Setup Screen ...

Страница 10: ...s a unique port to which the multicast packet will be sent Channel Hops is the number of routers that the packet will penetrate before being stopped and allowed to propagate no further The Multicast Address and Port Number must match those set within the console It is Okay to use the same Multicast Address and Port number in multiple NEO devices The base IP address is used to differentiate the sou...

Страница 11: ...econds that the input is allowed to stabilize from first change detection to final sampling The timer resolution is only 20ms so multiples of 20ms must be used Other values will work but give no finer resolution Once all values have been set press the Submit button to send the values to the NEO Save to EEPROM to make them permanent Section 3 9 Figure 5 Input Debounce Settings ...

Страница 12: ...y The parameters of the NEO are delineated by a dash between each value The values correspond to the entry fields per line of the NEO setup screen shown in Figure 7 Note that RX traffic is a single direction copy Packets received are copied only to the RX MCast address Note that traffic received to the RX multicast address will be recopied back out Since there should only be one receive source on ...

Страница 13: ...13 Figure 7 Echo Packet Setup ...

Страница 14: ... NEO to be copied to another over the network Simply enter the IP address of the unit to copy the parameters from and press the submit button The parameters will be copied The only parameters that are not copied are the PIN number IP address and Mask Figure 8 Clone from Other NEO ...

Страница 15: ...hange The PIN number is the password required to enter the setup mode of the NEO The default is no PIN number The PIN number is a 4 digit number that must be entered twice and then submitted Figure 9 Set PIN Number ...

Страница 16: ...M As each group of settings are changed and submitted they still must be saved to EEPROM to be stored permanently Some settings require reboot of the device to take effect These are primarily IP parameters Figure 10 Save to EEPROM ...

Страница 17: ...17 4 BILL OF MATERIAL AND SCHEMATICS ...

Страница 18: ...fication Is a proprietary product of TELEX Lincoln NE and shall not be released disclosed nor duplicated without the written permission of TELEX Telex Communications INC Lincoln Nebraska USA APPROVALS DR BY SBC DATE 09 16 2003 PROD CHK APPD 879796 REV LEVEL PCB ASSY NEO 10 TITLE PART NO 1 LN BE PAGE 1 OF 5 ...

Страница 19: ...26 D28 D30 D32 D33 19 10 LED RT ANG DUAL VERT LED RED 760506 D9 D12 D15 D18 D21 D24 D27 D29 D31 D34 20 1 FUSE SMT FUSE WITH HOLDER 5A SLO BLO 7101052T F44 21 16 FERRITE 0805 FERRITE BEAD 723511T FB1 FB2 FB3 FB4 FB5 FB6 FB7 FB8 FB9 FB10 FB11 FB12 FB13 FB14 FB22 FB23 22 1 FERRITE COMMON MODE FB 724039T FB44 23 1 CONN EMULATION HEADER 640125 J1 24 1 CONN 20 PIN SURFACE MOUNT HEADER DO NOT PLACE J12 2...

Страница 20: ... 47 15 RES 47 OHMS 0805 5 102506470T R35 R37 R38 R40 R41 R42 R44 R45 R46 R47 R48 R50 R51 R52 R57 48 4 RES 0805 1k 1 102515200T R39 R132 R135 R142 49 1 RES 22 1K 0603 1 723481333T R49 50 2 RES 220 OHMS 0805 5 102506221T R55 R56 51 2 RES 470 OHMS 0603 723488471T R59 R58 52 1 RES 4 7K 0603 723488472T R63 53 2 RES 30 1K 1 0603 723481346T R75 R13 54 1 RES 33 2K 1 0603 723481350T R76 55 1 RES 2 2M 0805 ...

Страница 21: ...PROVALS DR BY SBC DATE 09 16 2003 PROD CHK APPD 879796 REV LEVEL PCB ASSY NEO 10 TITLE PART NO 1 74 1 IC Intel LXT791ALC 760533 U49 75 5 IC 74LCX245 Bi Directional 8bit Bus Chip 760255 U5 U9 U10 U11 U15 76 1 IC TC7S32FU 760503S U6 77 2 IC TC7S08FU 760504S U7 U21 78 1 IC TPS70102PWP 760505S U8 79 1 XTAL 44 2368MHz 3 3V OSC 780191S Y1 80 1 XTAL 25 000MHZ SMT 780189S Y5 81 X 1 PCB PRINTED CIRCUIT BOA...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ...r consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives the customer specific legal rights and there may be other rights which vary from state to state Factory Service Center TELEX Communications Inc Vega Signaling Products 8601 East Cornhusker Highway Lincoln Nebraska 68507...

Отзывы: