INSTRUCTION MANUAL

 

Non-contacted Infrared 

forehead thermometer 

Model No.: IR-08MT

 

Revision: V1.0 

Date of issue: 2022-7-22 

 

 

 
 

 

 

 

Read this instruction manual carefully before use 

Содержание IR-08MT

Страница 1: ...Read Before Use 1 20 File No IR IM 001 VEGA TECHNOLOGIES INC INSTRUCTION MANUAL Non contacted Infrared forehead thermometer Model No IR 08MT Revision V1 0 Date of issue 2022 7 22 Read this instruction...

Страница 2: ...evice 3 3 Product description 4 4 Product features 5 5 Device specifications 5 6 Operating Instructions 7 7 Cleaning Disinfecting 10 8 Storage Maintenance Repair 10 9 TROUBLESHOOTING 11 10 Safety prec...

Страница 3: ...mperature gun for measuring human body temperature The product is widely used in schools customs hospitals families Easy to use mode selection The Non contacted Infrared forehead thermometer is intend...

Страница 4: ...Please Read Before Use 4 20 File No IR IM 001 3 Product description 3 1 Visual appearance and structure LED ON OFF button Measure temperature button Sensor Enclosure Battery slot Positive pole Negati...

Страница 5: ...oltage indication With AAA size LR03 alkaline battery 2pcs Optional storage case and carrying bag for easy storage 5 Device specifications NO Item Specification 1 Operation mode Continuous mode 2 Meas...

Страница 6: ...erature mode One Bi emits when body temperature 37 5 Six Bi emits when body temperature 37 5 16 Automatic shut off Stop operating the device it wills automatic shut off after 20 5 seconds 17 Low power...

Страница 7: ...zer At this time the measurement can start Press the button to start the measurement B Switch off After startup press M button and then the unit turn off in the Direct Mode After startup the unit will...

Страница 8: ...M button and the device switch off Then operated once again according the chapter adjust mode 6 1 4 Memories recall When the device is startup and displays on the screen the device defaults to display...

Страница 9: ...the result will display in the LED screen If you need to measure the person temperature please choice the adjust mode and the LED screen will display the symbol Please see the chapter 6 1 3 Direct mod...

Страница 10: ...lens and the LED Do not put the device into the water cleaning in order to avoid damage to the device use cotton swabs dipped in alcohol or using alcohol content of 70 cotton cloth or cotton to cleani...

Страница 11: ...he patient or the user can replace of batteries and the children use or replace the battery need under the adult supervision 8 3 Repair Never open or attempt to repair the device by yourself as otherw...

Страница 12: ...ter for signs of damage or wear before each use Damaged or worn thermometer should not be used Under any circumstances the temperature taking result is ONLY for reference Before taking any medical act...

Страница 13: ...es that can be swallowed Keep children away from packaging materials risk of suffocation Store the parts in a clean location for avoiding infection Do not use the device after exercising and need to r...

Страница 14: ...o as not to damage the body of the unit 10 4 Cleaning Cautions Use the cotton buds to clean the probe inside when it has dirt Do not use water or fingers to contact with the probe directly Do not imme...

Страница 15: ...ted to misuse improper operation accidental damage or unauthorized repairs and is not extended to charges of or for labor repairs All items returned must be properly packaged and shipped prepaid by th...

Страница 16: ...w The customer or the user of the device should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The device us...

Страница 17: ...ins power quality should be that of a typical commercial or hospital environment If the user of the device requires continued operation during power mains interruptions it is recommended that the devi...

Страница 18: ...to 800MHz d 2 3 P 800MHz to 2 5GHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in m...

Страница 19: ...er frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Table 5 refer...