Loop Control
The
Loop Control
button becomes available on the right side menu when any Ethernet application (V-SAM, RFC 2544, Throughput,
BERT) is selected. Press the
Loop Control
button to configure loop up and loop down commands necessary to control a far-end unit.
The loop up command contains information about the test layer. Looping back test traffic is possible as follows:
Layer 1:
All incoming traffic is looped back unchanged
Layer 2:
All incoming unicast traffic is looped back with the MAC source and destination addresses swapped
Layers 3 & 4:
All incoming unicast traffic is looped back with MAC/IP source and destination addresses swapped
To configure loopback control on the unit, select from the following options under
Partner Address
:
MX Discovered:
Lists MX discovered devices. Select from the list of discovered devices to loop up/down.
User Defined:
Input the destination IP address of the far-end device.
OAM Discover
: Lists OAM discovered devices. Select from the list of discovered devices to loop up/down.
X-loop
: Loops up non-VeEX networking equipment.
Remote Partner Control
The
Peer-to-Peer
option is available only for RFC 2544 testing. For more information on
Peer-to-Peer
mode, please see
OAM Discover
Like MX Discover, OAM Discover can also be used to discover far-end test units without manually configuring the local or remote
unit's destination address. If OAM is enabled on the test set, any link partner that supports the IEEE 802.3ah protocol will be
discovered automatically and displayed under the
OAM Discover
tab. To access OAM Discover:
1. Go to
Throughput
>
OAM
>
Link OAM
and tap on the 802.3ah check box to activate Link OAM. Select Active from the
OAM
Mode
drop-down menu (only Active mode can send loop commands).
RXT-3900 e-Manual D07-00-111P Rev A00
Содержание RXT3900
Страница 1: ...RXT 3900 e Manual D07 00 111P Rev A00...
Страница 19: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 35: ...Tx Structure Setup Graphical Mode Tx Payload Setup Tx Pattern Setup RXT 3900 e Manual D07 00 111P Rev A00...
Страница 50: ...RXT 3900 e Manual D07 00 111P Rev A00...
Страница 74: ...RXT 3900 e Manual D07 00 111P Rev A00...
Страница 75: ...RXT 3900 e Manual D07 00 111P Rev A00...
Страница 119: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 240: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 282: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 294: ...Go back to top Go back to TOC 13 15 IP Monitoring RXT 3900 e Manual D07 00 111P Rev A00...
Страница 296: ...Net Wiz Trace Route Setup Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 363: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...
Страница 377: ...Go back to top Go back to TOC RXT 3900 e Manual D07 00 111P Rev A00...