Frame Size (bytes):
Enter the frame size when a Layer 2, 3, or 4 BERT is selected
Frame size configuration is not available for Layer 1 BERT
Frame sizes can be from 64 bytes to 1518 bytes, in addition to jumbo frames up to 10000 bytes
BW (Transmit Bandwidth):
Configure the transmit rate for the test
When traffic flow is equal to Burst, two burst bandwidths are configured with burst time
When traffic flow is equal to Ramp, starting and an ending bandwidth are configured along with the
bandwidth step size and duration
BERT Setup - Constant Traffic
Note: Frame Size Limitations
Layer 1 framed mode - Frame size configuration is not available.
Layer 1 unframed mode - Traffic profile is constant at 100% bandwidth.
13.2.1.3 Error Injection
( This description is for 10GE only)
Error injection can be performed during testing. The error type and injection rate are configured in the Error Injection
tab.
Error type:
Select from Bit, CRC, IP Checksum (Layer 3, 4 only), Pause, TCP/UDP Checksum (Layer 4 only).
With Pause selected, the unit will transmit a pause frame when
Error Injection
icon is pressed. The Pause time
duration is configurable in units of 512 bit time. At Gigabit Ethernet speed, this is equivalent to 512 ns. For
example, if pause time is set to 1000, the pause duration will be set to 1000x512 ns.
Injection Flow:
The error injection flow determines how the selected errors will be injected.
Select a single error injection or specific count.
Count:
Configures the error count via a numeric keypad.
RXT-6200_RXT6000e_Module_Manual
Page 224 of 387
Содержание RXT-6000e
Страница 1: ......
Страница 39: ...Rx Pattern Setup Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 39 of 387...
Страница 48: ...Tx Interface Setup Tx Structure Setup Text Mode RXT 6200_RXT6000e_Module_Manual Page 48 of 387...
Страница 61: ...RXT 6200_RXT6000e_Module_Manual Page 61 of 387...
Страница 97: ...RXT 6200_RXT6000e_Module_Manual Page 97 of 387...
Страница 199: ...RXT 6200_RXT6000e_Module_Manual Page 199 of 387...
Страница 200: ...Go back to top Go back to TOC Errors Alarms Page 2 RXT 6200_RXT6000e_Module_Manual Page 200 of 387...
Страница 232: ...BERT Results Signal Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 232 of 387...
Страница 254: ...Background Results Per Stream Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 254 of 387...
Страница 267: ...Event Log Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 267 of 387...
Страница 327: ...Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 327 of 387...
Страница 351: ...Go back to top Go back to TOC RXT 6200_RXT6000e_Module_Manual Page 351 of 387...