background image

 Introduction

Contractor Certification Requirements

4

Contractor Certification Requirements

Veeder-Root requires the following minimum training certifications for contractors who will install and setup the 
equipment discussed in this manual:

Installer (Level 1) Certification:

 Contractors holding valid Installer Certification are approved to perform wiring and 

conduit routing; equipment mounting; probe, sensor and carbon canister vapor polisher installation; wireless equipment 
installation; tank and line preparation; and line leak detector installation.

ATG Technician (Level 2/3 or 4) Certification:

 Contractors holding valid ATG Technician Certifications are approved 

to perform installation checkout, startup, programming and operations training, system tests, troubleshooting and 
servicing for all Veeder-Root Series Tank Monitoring Systems, including Line Leak Detection. In addition, Contractors 
with the following sub-certification designations are approved to perform installation checkout, startup, programming, 
system tests, troubleshooting, service techniques and operations training on the designated system. 

• Wireless  2
• Tall Tank

Warranty Registrations

 may only be submitted by selected Distributors.

Safety Precautions

The following safety symbols may be used throughout this manual to alert you to important safety hazards and 
precautions.

GENERAL

Ensure that all local council and regulations are complied with. Also ensure that all recognized safety codes are 
followed.

EXPLOSIVE

Fuels and their vapors are extremely explosive if ignited.

FLAMMABLE

Fuels and their vapors are extremely flammable.

ELECTRICITY

High voltage exists in, and is supplied to, the device. A 
potential shock hazard exists.

TURN POWER OFF

Live power to a device creates a potential shock 
hazard. Turn Off power to the device and associated 
accessories when servicing the unit.

WARNING indicates a hazardous situation 
which, if not avoided, could result in death or 
serious injury.

USE SAFETY BARRICADES

Unauthorized people or vehicles in the work area are 
dangerous. Always use safety cones or barricades, 
safety tape, and your vehicle to block the work area.

INJURY

Careless or improper handling of materials can result in 
bodily injury..

GLOVES

Wear gloves to protect hands from irritation or injury.

WEAR EYE PROTECTION

Wear eye protection when working with pressurized 
fuel lines or epoxy sealant to avoid possible eye injury.

WEAR RESPIRATOR

Wear breathing protection when working in the 
presence of harmful vapors.

READ ALL RELATED MANUALS

Knowledge of all related procedures before you begin 
work is important. Read and understand all manuals 
thoroughly. If you do not understand a procedure, ask 
someone who does.

NOTICE is used to address practices not 
related to physical injury.

OFF

WARNING

NOTICE

Содержание DEF

Страница 1: ...Manual No 577014 344 Revision C Installation Manual DEF Recirculation Control...

Страница 2: ...f any damages and or shortages within 30 days of receipt of the shipment as stated in our Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Fax Bill of Lading to V R Customer Service at 800 234 5...

Страница 3: ...ensor Field Wiring 9 Sealing Field Connections 9 Wiring Run Through Rigid Conduit 9 Direct Burial Cable 10 Console Wiring Precautions 10 Connecting Sensor Wiring To The Console 11 Figures Figure 1 DEF...

Страница 4: ...dependently or concurrently with the DEF pump Figure 1 DEF Fluid Temperature Monitoring Components DEF Dispenser DEF Dispenser Heat Trace manufacturer required GFI EPD circuit breaker per NEC Article...

Страница 5: ...install intrinsically safe apparatus use the specific control drawing that appears on the nameplate of the applicable associated apparatus ATG Console The control drawings contain information related...

Страница 6: ...Operator s Manual CLASS I Division 1 Group D CLASS 1 Zone 0 Hazardous Location Intrinsically Safe Apparatus DEF Temperature Sensor Intrinsically Safe Wiring White Brown Black Black I S Rigid Conduit...

Страница 7: ...o alert you to important safety hazards and precautions GENERAL Ensure that all local council and regulations are complied with Also ensure that all recognized safety codes are followed EXPLOSIVE Fuel...

Страница 8: ...energy limited system This system makes the sensors suitable for use in hazardous locations Sensor wiring is intrinsically safe only when connected to the TLS console All sensor wiring must be contai...

Страница 9: ...service this equipment in accordance with these codes regulations and standards may lead to legal citations with penalties or affect the safe use and operation of the equipment ISO STANDARD FOR DEF Th...

Страница 10: ...must be observed Keep fluid away from the motor cable Follow internal instructions Wear protective clothing face and breathing protection protective gloves etc De ploy safety barricades around work a...

Страница 11: ...d install it into the bushing 4 Loosen the nut on the tube fitting and insert the temperature sensor into the tube fitting enough but not more than 6 to ensure the 1 4 diameter section of the sensor i...

Страница 12: ...ugh the seal off box the conduit attaching the junction box to the seal off box and into the junction box 2 Using wire nuts connect the two wires from the sensor to the two wires coming from the conso...

Страница 13: ...nec tors without reprogramming that device 879 38 eps To console Tie wrap Wire nuts From probe sensor or transducer A C B Make sure that the ends of cable sheathing are sub merged in sealant nt t t nt...

Страница 14: ...sensor is NOT grounded 3 Write in the device name for each wire connection on the connector block in the module s wiring label attached to the inside of the door 4 Make sure that you loop the wire nea...

Страница 15: ...m Relay Contact Ratings 120 240 Vac 5A 30 Vdc 5A Fuse ratings 5A 250 Vac Type T Slo Blo TLS 450PLUS TLS XB TLS4 Control Of DEF Piping Heat Trace Circuitry If Required HV Relay Outputs Control Of DEF P...