Dispenser Control Interface Wiring
Installing the Dispenser Pan Sensor
8
2.
Place the cover on the junction box and ensure that all cover screws are replaced
and tight.
3.
Visually check to be sure that the security plugs, Dispenser Control Interface, and
all wiring and cables are secure.
4.
Restore AC power to the junction box.
Figure 3.
Typical Dispenser Control Interface Wiring Diagram
Figure 4.
Typical Installation Wiring Diagram for Dispenser Control Interface to a
Dresser-Wayne Dispenser (120 VAC)
8
45-
3
DI
S
PEN
S
ER
DI
S
PEN
S
ER POWER
NEUTRAL
120 VAC
COMBINED MAXIMUM:
120V, 8A RESISTIVE,
1A PILOT DUTY
RELAY CONTACT RATING
RED
PAN
SENSOR
DISPENSER
CONTROL
INTERFACE
WHT
BLK
RED
INPUT:
120VAC
4.5 VA
50/60 Hz
NEUTRAL
COMBINED MAXIMUM:
120V, 8A RESISTIVE,
1A PILOT DUTY
RELAY CONTACT RATING
PAN
SENSOR
DISPENSER
CONTROL
INTERFACE
INPUT:
120VAC
4.5 VA
50/60 Hz
NEUTRAL