manualshive.com logo in svg
background image

DC CHARGER

AC CHARGER

 

 

 

 

                    FIGURE 5

RECHARGING

AC and DC recharge requires use of these supplied  

recharge adapters. Do not charge spotlight using  

any other adapters (see figure 5).

 

 

 

 

AC RECHARGE

Make sure that the AC source is 110/120 volts, 60 Hz.

WARNING:

 Use the supplied AC recharge adapter; do not substitute with any other. AC  

recharge requires the use of the supplied AC recharge adapter that supplies12 volts DC.

DURING AC RECHARGE/OR DC RECHARGE:

a) Never turn on while charging.

b) After recharge – disconnect cord and wait 5 minutes before use.
1. Lift the rubber plug from the recharge port (see Figure 3). It is there to keep out dust and  

  moisture.

2. Connect the wall transformer charger to an AC source.

3. Plug the adapter’s barrel connecter into the recharge port located near the handle.

4. Recharge for 15 hours maximum.

5. After recharge, disconnect the barrel connector from the recharge port and store the adapter.

6. Replace the rubber plug in the recharge port.

DC RECHARGE

Make sure the DC source (jump starter, battery pack, vehicle accessory socket, etc) is 12 volt DC. 

The DC source should be able to supply at least 10 amps at 12 volt DC.

WARNING:

 Use the supplied DC recharge adapter, do not substitute.

DC recharge requires the use of the supplied DC recharge adapter. Do not substitute with any other.

1. Lift the rubber plug from the recharge port. It is there to keep out dust and moisture.

2. Connect the DC recharge adapter’s DC plug to a 12 volt DC source.

3. Plug the adapter’s barrel connecter into the recharge port located near the handle.

4. Recharge for 3 hours maximum.

5. After recharge, disconnect the barrel connector from the recharge port and store the adapter.

6. Replace the rubber plug in the recharge port.

DC OPERATION AND RECHARGE

You may operate the spotlight or area light directly from any 12 volt DC external power source 

supplying at least 10 amp capacity. The internal battery will be recharged while operating the 

spotlight or area light from external DC power source.

5. 

PERIODIC MAINTENANCE

All batteries lose charge over time, especially when they are warm. AC recharge is recommended 

every two months, when not in frequent use. Use the AC recharger and charge for the recom-

mended time. If the unit gets dirty gently clean the outer surface of the spotlight unit with a soft 

cloth moistened with a mild solution of water and detergent. Periodically inspect the condition of 

recharge adapters, connectors, and wires. Replace any components that may have become worn 

or broken.

6. 

PARTS REPLACEMENT

Three parts are replaceable by users. The quartz halogen bulb and sealed lead acid battery are pro-

prietary and are available through Vector Manufacturing. A substitute 12 volt H3 55 watt bulb may be 

used instead of a Vector bulb. These can also be purchased from popular automotive parts suppliers 

nationwide. The DC charging adapter fuse is replaceable. Contact Vector Manufacturing’s Technical 

Support Department for replacement parts and any additional information that you may need. They 

Содержание VEC37R

Страница 1: ...NINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 4140 SW 28th Way FT LAUDERDALE FL 33312 Tel 954...

Страница 2: ...is breakable 8 Do not drop or throw spotlight it contains glass and a sealed lead acid battery 9 Dispose of unusable batteries in a responsible manner see battery disposal section 10 Make sure that du...

Страница 3: ...button located near two handle screws and rotating the handle to the new position When the handle is close to the body of the light folded the Rescue Spot is carried with the weight of the unit below...

Страница 4: ...DC recharge adapter s DC plug to a 12 volt DC source 3 Plug the adapter s barrel connecter into the recharge port located near the handle 4 Recharge for 3 hours maximum 5 After recharge disconnect th...

Страница 5: ...ing adapters 2 Lift up the recharge port plug from the recharge port 3 Pull off the rubber bezel to reveal two small Phillips head screws 4 Using the screwdriver remove counterclockwise the two screws...

Страница 6: ...the battery and recharge adapters Double check battery polarity before reassembly 7 Replace handle stand and recharge port assemblies in one half of the housing body Make sure wires and connectors do...

Страница 7: ...charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to us...

Страница 8: ...2003 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA AHB 073003...

Отзывы: