CONTROLS AND INDICATORS

There are four LED indicators and four switches that make up the controls and indicators for this charger. When a button
is pressed or the charger changes mode or charging stage, the charger sounds a single beep tone. Refer to Figure 4A
for locations of items on the Controls and Indicators panel.

FIGURE 4A

DIGITAL DISPLAY

FIGURE 4B

Circulating pattern

WARNINGS:

THERE ARE NO USER-SERVICEABLE PARTS IN THIS CHARGER. IN THE EVENT OF ANY OPERATING PROBLEM THAT THE
CHARGER’S BUILT-IN CIRCUIT PROTECTION CANNOT HANDLE, DO NOT OPEN THE
UNIT!  IT MUST BE RETURNED TO VECTOR FOR PROFESSIONAL TESTING AND REPAIR. OPENING THE UNIT WILL VOID THE
MANUFACTURER'S WARRANTY.

From right to left the function switch buttons are:

ON/OFF - 

this prepares the charger to be placed in any of the operating modes. Pressing the ON/OFF button

immediately stops any operating mode and the display shows the circulating pattern (FIGURE 4B)

2/6/12A 

allows the user to select the charger rate based on battery size. This selection and actual battery charge rate

are monitored by the microprocessor and will stop charging if the rate is too fast or too slow for battery size or

condition.

BATTERY RECONDITION 

is an automatic mode that once started continues for 24 hours and then stops. A series of

electronic pulses are sent into the battery enabling the sulfates to once again accept and release energy so the battery will

perform at a greater capacity. More than 24 hours may be needed to restore. If 5 cycles does not improve battery

performance, discontinue and recycle the battery.

ALTERNATOR VOLTAGE CHECK 

Enables a five second check that measures the battery voltage. This check is repeated at

electrical load and "no load" levels and allows the user to determine if the alternator can keep up with load demands.

The results can indicate alternator service may be required.

Periodic reconditioning is recommended to maintain a battery’s optimum performance.

Содержание VEC1088 A

Страница 1: ...to persons 3 To reduce risk of damage to electric plug and cord pull by plug rather than cord when disconnecting charger 4 An extension cord should not be used unless absolutely necessary Use of an improper extension cord could result in a risk of fire and electric shock If extension cord must be used make sure a Pins on plug of extension cord are the same number size and shape as those of plug on...

Страница 2: ...plug The plug must be plugged into a properly installed and grounded 110 120VAC outlet in accordance with all local codes and ordinances See Figure 1 This battery charger is for use on a 110 120VAC circuit and has a grounding plug that looks like the plug shown in FIGURE 1A If a properly grounded outlet is not available a temporary adapter like the adapter shown in FIGURE 1B may be used to connect...

Страница 3: ... output clamps only after unplugging AC cord from outlet 2 Never allow clamps to touch each other 3 Attach clamps to battery posts and check for secure connection This will hold clamps securely on terminals and helps to reduce risk of sparking FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY a Position A...

Страница 4: ... remains constant while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe effective battery charge level step down regulation mode Ideal for topping off batteries that have been in storage At the conclusion o...

Страница 5: ...ny of the operating modes Pressing the ON OFF button immediately stops any operating mode and the display shows the circulating pattern FIGURE 4B 2 6 12A allows the user to select the charger rate based on battery size This selection and actual battery charge rate are monitored by the microprocessor and will stop charging if the rate is too fast or too slow for battery size or condition BATTERY RE...

Страница 6: ... on the back of charger FIGURE 5 Below the Digital Display are series of four LEDS that light on the following conditions FAULT Lights when any of several faults are detected see F01 through F05 Codes as described above If the Fault LED lights refer to TROUBLESHOOTING for details REV POLARITY Lights when clamps are incorrectly connected to battery terminals CHARGING COMPLETE Indicates Battery is c...

Страница 7: ...charge rate to appropriate setting 2 6 12A according to battery size POSITIVE GROUNDED VEHICLE Connect the NEGATIVE BLACK charger clamp to the NEGATIVE NEG N ungrounded battery post Then connect the POSITIVE RED battery clamp to the vehicle chassis or engine part away from the battery Do not connect the clamp to the carburetor fuel lines or sheet metal body d Plug battery charger power cord into g...

Страница 8: ...d to accept a charge F02 and to ensure the battery can take a charge If code F03 is displayed change to the BATTERY RECONDITION MODE Whenever a lead acid battery begins to discharge lead sulfate an insulator begins to build up on the battery s internal plates This reduces the ability of the battery to hold a full charge When that battery has an immediate charge most of the lead sulfate is dissolve...

Страница 9: ...mperature and engine idle speed It is recommended to check your alternator when it is known to be operating properly to verify that this check is valid for your particular vehicle Check only 12V systems Checking 24 or 36V systems will damage charger NOTE It may be that someone has added a number of accessory loads on the charging system thereby increasing current demand from the alternator MAKE SU...

Страница 10: ... lead sulfate To determine if a sulfated battery can be saved follow the instructions in Battery Recondition INTERNAL SHORT CELL BATTERY F01 If the battery being charged has an internal shorted cell the FAULT LED will light If FAULT LED light comes on Vector recommends you take your battery to a certified automotive service center for evaluation BATTERY NOT ACCEPTING A CHARGE Make sure that the ch...

Страница 11: ...5 0 2 AMPS 7 HRS 13 HRS NR NR 6 AMPS 2 5 HRS 5 HRS 7 HRS 9 HRS 12 AMPS 1 2 HRS 2 5 HRS 3 2 HRS 4 6 HRS Not recommended The times shown in the chart above are approximate and refer to an average automotive battery For smaller batteries the charge time should be adjusted using the formula shown below and adding 1 hour to the time calculated To estimate charging time for a discharged battery divide t...

Отзывы: