background image

2

VEC1088 A

REV101103

PERSONAL PRECAUTIONS AND SAFETY

1. Another person should be close enough to come to your aid when you work near a lead-acid battery.
2. Fresh water and soap should be nearby in case battery acid contacts skin, clothing, or eyes.
3. Wear eye protection and protective clothing. Avoid touching eyes or skin while working with a battery. If acid particles

or corrosion gets into eyes immediately flood eye with cold water (Eye Wash Station) for at least 10 minutes and get
medical attention immediately.

4. If battery acid contacts skin or clothing, wash immediately with soap and water.
5. NEVER smoke or allow a spark or flame in vicinity of battery or engine.
6. CAUTION: Dropping metal tool or other object onto battery may cause spark, short-circuit battery or other electrical

components and may cause explosion.

7. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead-acid battery.

Lead-acid batteries can produce a short-circuit current high enough to cause a severe burn.

GROUND AND AC POWER CORD CONNECTION

Charger should be grounded to reduce risk of electric shock. Charger is equipped with an AC cord having grounding
conductor and a grounding plug. The plug must be plugged into a properly installed and grounded 110/120VAC outlet
in accordance with all local codes and ordinances. (See Figure 1.)

This battery charger is for use on a 110/120VAC circuit, and has a grounding plug that looks like the plug shown in
FIGURE 1A. If a properly grounded outlet is not available, a temporary adapter (like the adapter shown in FIGURE 1B),
may be used to connect this plug to a two-pole receptacle as shown in FIGURE 1B. The temporary adapter should be
used ONLY until a properly grounded outlet can be installed by a qualified electrician.

The green-colored rigid ear or tab extending from adapter must be connected to a properly grounded outlet.  Make
certain it is grounded. If necessary, replace original outlet cover plate screw with a longer screw that will secure adapter
ground tab to outlet cover plate and connect to grounded outlet.

FIGURE 1A

FIGURE 1B

GROUNDING PIN (A)

ADAPTER (B)

GROUNDING
MEANS

METAL SCREW

USE OF AN ADAPTER IS NOT ALLOWED IN CANADA. IF A GROUNDING TYPE RECEPTACLE IS NOT AVAILABLE, DO
NOT USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN

DANGER! 

NEVER

alter AC cord or plug – if it will not fit outlet, have proper outlet installed by a qualified electrician.

Improper connection may result in an electric shock.

DANGER! 

Before using adapter as shown (FIGURE 1B), be sure the center screw of outlet plate is grounded.

Содержание VEC1088 A

Страница 1: ...to persons 3 To reduce risk of damage to electric plug and cord pull by plug rather than cord when disconnecting charger 4 An extension cord should not be used unless absolutely necessary Use of an improper extension cord could result in a risk of fire and electric shock If extension cord must be used make sure a Pins on plug of extension cord are the same number size and shape as those of plug on...

Страница 2: ...plug The plug must be plugged into a properly installed and grounded 110 120VAC outlet in accordance with all local codes and ordinances See Figure 1 This battery charger is for use on a 110 120VAC circuit and has a grounding plug that looks like the plug shown in FIGURE 1A If a properly grounded outlet is not available a temporary adapter like the adapter shown in FIGURE 1B may be used to connect...

Страница 3: ... output clamps only after unplugging AC cord from outlet 2 Never allow clamps to touch each other 3 Attach clamps to battery posts and check for secure connection This will hold clamps securely on terminals and helps to reduce risk of sparking FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY a Position A...

Страница 4: ... remains constant while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe effective battery charge level step down regulation mode Ideal for topping off batteries that have been in storage At the conclusion o...

Страница 5: ...ny of the operating modes Pressing the ON OFF button immediately stops any operating mode and the display shows the circulating pattern FIGURE 4B 2 6 12A allows the user to select the charger rate based on battery size This selection and actual battery charge rate are monitored by the microprocessor and will stop charging if the rate is too fast or too slow for battery size or condition BATTERY RE...

Страница 6: ... on the back of charger FIGURE 5 Below the Digital Display are series of four LEDS that light on the following conditions FAULT Lights when any of several faults are detected see F01 through F05 Codes as described above If the Fault LED lights refer to TROUBLESHOOTING for details REV POLARITY Lights when clamps are incorrectly connected to battery terminals CHARGING COMPLETE Indicates Battery is c...

Страница 7: ...charge rate to appropriate setting 2 6 12A according to battery size POSITIVE GROUNDED VEHICLE Connect the NEGATIVE BLACK charger clamp to the NEGATIVE NEG N ungrounded battery post Then connect the POSITIVE RED battery clamp to the vehicle chassis or engine part away from the battery Do not connect the clamp to the carburetor fuel lines or sheet metal body d Plug battery charger power cord into g...

Страница 8: ...d to accept a charge F02 and to ensure the battery can take a charge If code F03 is displayed change to the BATTERY RECONDITION MODE Whenever a lead acid battery begins to discharge lead sulfate an insulator begins to build up on the battery s internal plates This reduces the ability of the battery to hold a full charge When that battery has an immediate charge most of the lead sulfate is dissolve...

Страница 9: ...mperature and engine idle speed It is recommended to check your alternator when it is known to be operating properly to verify that this check is valid for your particular vehicle Check only 12V systems Checking 24 or 36V systems will damage charger NOTE It may be that someone has added a number of accessory loads on the charging system thereby increasing current demand from the alternator MAKE SU...

Страница 10: ... lead sulfate To determine if a sulfated battery can be saved follow the instructions in Battery Recondition INTERNAL SHORT CELL BATTERY F01 If the battery being charged has an internal shorted cell the FAULT LED will light If FAULT LED light comes on Vector recommends you take your battery to a certified automotive service center for evaluation BATTERY NOT ACCEPTING A CHARGE Make sure that the ch...

Страница 11: ...5 0 2 AMPS 7 HRS 13 HRS NR NR 6 AMPS 2 5 HRS 5 HRS 7 HRS 9 HRS 12 AMPS 1 2 HRS 2 5 HRS 3 2 HRS 4 6 HRS Not recommended The times shown in the chart above are approximate and refer to an average automotive battery For smaller batteries the charge time should be adjusted using the formula shown below and adding 1 hour to the time calculated To estimate charging time for a discharged battery divide t...

Отзывы: