PERSONAL PRECAUTIONS AND SAFETY

1. Another person should be within range of your voice or close enough to come to your aid when you work near a 

lead-acid battery.

2. Fresh water and soap should be nearby in case battery acid contacts skin, clothing, or eyes.
3. Wear complete eye protection and clothing protection. Avoid touching eyes while working with a battery. Acid, acid

particles or corrosion may get into eyes. Immediately flood eye with cold water (Eye Wash Station) for at least 10 

minutes and seek medical attention immediately.

4. If battery acid contacts skin or clothing, wash immediately with soap and water.
5. NEVER smoke or allow a spark or flame in vicinity of battery or engine.

6. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead acid battery.

A lead-acid battery can produce a short-circuit current high enough to cause a severe burn.

AC POWER CORD CONNECTION

Charger is equipped with an AC cord with a "polarized" plug. The plug must be plugged into a properly installed
110/120VAC polarized outlet in accordance with all local codes and ordinances. This battery charger is for use with a
110/120VAC polarized plug ONLY

CAUTION:

Dropping a metal tool onto battery. It might spark or short-circuit battery or other

electrical part 

that may cause explosion.

DANGER!

NEVER alter AC cord or plug – if it will not fit outlet, have proper outlet installed

by a qualified electrician. Improper connection may result in an electric shock. 

Содержание VEC1086 A

Страница 1: ... be used unless absolutely necessary Use of an improper extension cord could result in a risk of fire and electric shock If extension cord must be used make sure a That pins on plug of extension cord are the same number size and shape as those of plug on charger b That extension cord is properly wired and in good electrical condition and c That wire size is AWG 16 16 gauge to 100 feet and AWG 14 f...

Страница 2: ...r allow a spark or flame in vicinity of battery or engine 6 Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery can produce a short circuit current high enough to cause a severe burn AC POWER CORD CONNECTION Charger is equipped with an AC cord with a polarized plug The plug must be plugged into a properly installed 110...

Страница 3: ...let 2 Never allow clamps to touch each other 3 Attach clamps to battery posts and check for secure connection This will hold clamps securely on terminals and helps to reduce risk of sparking FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY a Position AC and DC cords to reduce risk of damage by hood door ...

Страница 4: ...se voltage absorption regulation charge the charging voltage remains constant while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer 3 Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermined level while current is adjusted for a safe effective 100 battery charge step down regulation mode This is ideal for...

Страница 5: ...complete see page 4 Pressing the 2 4 6A switch a second time will advance the charge rate to 4A then 6A Pressing the button switch again will turn OFF the charger output and all LED bars will be unlit To return to 2A press the Charge Rate button switch This charger has three user selected charge rates 2 4 and 6 amps Pressing the 2 4 6A switch button selects the desired charge rate The selected Cha...

Страница 6: ...sconnect cables and clamps in reverse order from which they were connected NOTE Use of Extension Cords When using an extension cord observe the following important safety information Before using any extension cord ensure that the wire size is at least 16 AWG for up to 100 feet and 14 AWG for longer than 100 feet Use only a good quality good condition UL approved extension cord and ALWAYS connect ...

Страница 7: ...size g When charging is complete disconnect cables and clamps in reverse order from which they were connected CHARGING TIMES The VEC1086 A fully automatic battery charger will automatically adjust the charge rate as the battery charges and stops charging when the battery is fully charged If you require some estimate of the time it takes to charge a battery refer to Appendix A page 9 for these deta...

Страница 8: ...ulfated Sulfated batteries cannot accept a high rate of charge since the internal plates are coated with lead sulfate To see if a battery in this condition can be saved take it to a service station or battery distributor for professional evaluation and service INTERNAL SHORT CELL BATTERY If the battery being charged has an internal shorted cell the FAULT LED will light If FAULT LED light comes on ...

Страница 9: ...F CHARGE 75 50 25 0 2 AMPS 7 HRS 13 HRS NR NR 4 AMPS 3 5 HRS 6 HRS 9 HRS 12 HRS 6 AMPS 2 5 HRS 5 HRS 7 HRS 9 HRS Not recommended The times shown in the chart above are approximate and refer to an average automotive battery For smaller batteries the charge time should be adjusted using the formula shown below and adding 1 hour to the time calculated To estimate charging time for a discharged batter...

Страница 10: ...return shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care...