background image

13

AC22

AC22-10-A/ AC22-15-A/ AC22-20-A

5A x 

3

5A

16

A

N H1H2

N

1

On

Off

F1 F2 F3

on/off

2

N

L

PE

N

L

PE

~

0 -10V

0 - 

10

V

HEA

T

ALARM WA

TE

R

IN

TERNAL

SENSOR

IR

M

Blue

Black 
Brown

~

Right motor

M

Blue

Black 
Brown

~

C3

Ru

n

C2

Lo

C1

Mi

d

Le

ft

 motor

Only 2 m ver

sion

PL221

0CA

PL2215CA

PL2220CA

C3

Ru

n

C2

Lo

C1

Mi

d

Содержание AC22

Страница 1: ...AC22 Art nr 172783 01 GB Installation and maintenance instruction for air curtains IMPORTANT Read these instructions before the product is installed and used Save the instructions for future use 2...

Страница 2: ...e product is used in the manner intended and in ac cordance with the instructions Application area The AC22 air curtain unit is supplied without heating with electrical heating or hot water heating Th...

Страница 3: ...twards to withstand the load Generally speaking the higher the load the greater the angle that is needed Basic setting fan speed The fan speed when the door is open is set using the control Note that...

Страница 4: ...than cleaning is necessary The level of cleaning can vary depending on local condi tions Undertake cleaning at least twice a year Inlet and exhaust grilles impeller and elements can be vacuum cleaned...

Страница 5: ...r coil is air free That there is enough water flow That incoming water is heated enough If the fault cannot be rectified please contact a qualified service technician Residual current circuit breaker...

Страница 6: ...ON Factory setting dip switches Units with water heating Dip switch 3 is used for PL2DR optional Factory setting dip switches Units with electrical heating and no heat Dip switch 3 is used for PL2DR o...

Страница 7: ...ting steps are tested in 10 second intervals which are indicated by lighted LEDs When the test is completed all LEDs will flash for 30 seconds Temperature control If the temperature exceeds 50 C the f...

Страница 8: ...40 183 78 165 40 1026 1536 2026 20 210 10 145 min 500 min 500 min 500 145 62 40 22 Cu 15 min 500 min 500 145 145 17 5 17 5 32 5 25 5 20 5 17 5 Gland Knock out Knock out Knock out Gland Fig 1 Fig 2 Gl...

Страница 9: ...9 AC22 Fig 3 Open the unit A B TX20 C...

Страница 10: ...10 AC22 30 mm 60 mm Fig 4 Fig 5 Minimum distance min 60...

Страница 11: ...11 AC22 min 500 mm Fig 6 Mounting with wall brackets Mounting with wall brackets A B D E C 20 35 75 210 33 8 3x 5 10 162 AC22 10 2 pcs AC22 15 2 pcs AC22 20 3 pcs...

Страница 12: ...r unit Length 1 m Units 2 pcs AC22 10 AC22 15 Pendulum brackets for mounting the unit suspended from the ceiling The pendulum brackets are covered by a white plastic duct to hide the cables The bracke...

Страница 13: ...6A N H1H2 N 1 On Off F1 F2 F3 on off 2 N L PE N L PE 0 10V 0 10V HEAT ALARM WATER INTERNAL SENSOR IR M Blue Black Brown C Right motor M Blue Black Brown C C3 Run C2 Lo C1 Mid Left motor Only 2 m versi...

Страница 14: ...5A 16A N H1H2 N 1 On Off F1 F2 F3 on off 2 N L PE N L PE 0 10V 0 10V HEAT ALARM WATER INTERNAL SENSOR IR M Blue Black Brown C Over heat cut out C C1 L2 PE L1 L N L3 400V 3N L2 PE L1 L N L3 230V PL2210...

Страница 15: ...PE 0 10V 0 10V HEAT ALARM WATER INTERNAL SENSOR IR C2 Over heat cut out C C1 L2 PE L1 L N L3 400V 3N Over heat C cut out PL2215CE08 PL2220CE10 M Blue Black Brown C Right motor M Blue Black Brown C C3...

Страница 16: ...N 1 On Off F1 F2 F3 on off 2 N L PE N L PE 0 10V 0 10V HEAT ALARM WATER INTERNAL SENSOR IR PL2210CW PL2215CW PL2220CW M Blue Black Brown C Right motor M Blue Black Brown C C3 Run C2 Lo C1 Mid Left mo...

Страница 17: ...2 F3 OUT PA2MLK C NC NO Motor alarm pot free contact M Blue Black Brown C Lo Mid Run Left motor Only 2 m version 5A x 3 5A 16A N H1H2 N 1 On Off F1 F2 F3 on off 2 N L PE N L PE 0 10V 0 10V HEAT ALARM...

Страница 18: ...t 556138 3166 VAT no SE556138316601 Postal Cheque Service 48 51 08 5 Bank Transfer 926 0365 Fax Int 46 451 410 80 E mail veab veab com Phone Int 46 451 485 00 Website www veab com NB We reserve us fro...

Отзывы: