5 Troubleshooting
Testing Instructions for CTC II
13
I
• Edi
/200
9
5
Troubleshooting
The following error messages may be displayed during
KITAS testing:
Error message
Cause / Action to be taken
1
Communication error
KITAS sensor is sending no echo or no
acknowledgement
Measures
–
Carry out an ohmic test for the KITAS sensor
cable and replace it if necessary.
–
Check the sender unit test cable and replace it if
necessary.
–
Carry out the KITAS testing procedure again.
–
If the error message continues to appear despite
these measures, replace the KITAS.
2
Initialisation error
No KITAS is being identified during the sender
check.
Measures
–
Carry out an ohmic test for the KITAS sensor
cable and replace it if necessary.
–
Check the sender unit test cable and replace it if
necessary.
–
Check the type of sensor that is connected.
Only the KITAS 2170 and KITAS 2171 are
supported.
–
Carry out the KITAS testing procedure again.
–
If the error message continues to appear despite
these measures, replace the KITAS.
! ERROR !
KITAS
COMM. ERROR
CONTINUE WITH KEY
! ERROR !
NO KITAS
CONTINUE WITH KEY