background image

Turn on the power at fuse or circuit box.

 

 

Turn off the power at fuse or circuit box

Installation Steps

The Position of Control Panel

Page 2 / 5

1. Unscrew the two bolt nuts (D), remove the two rubber pads (E) and the crossbar unit (A) from the backplate.

2. Attach the crossbar unit (A) to the outlet box by using two mounting screws (B). Adjust the length of the

    preinstalled fixture mounting screws if necessary.

    

Note: Make sure that the fixture mounting screws are lined up horizontally to make the fixture level.

3. Pull out the source wires from the outlet box. Make wire connections using wire connectors (C) as follows: 

     • Connect the hot wire (black insulation) from the fixture to the black wire from the power source.

     • Connect the neutral wire (white insulation) from the fixture to the white wire from the power source. 

     • Attach the fixture ground wire (bare wire) to the crossbar unit (A) with the green ground screw, then 

       depending on local code, connect it to the house ground wire with the wire connector (C).

     Carefully put all of the wires back into the outlet box.

4. Attach the backplate of the fixture to the crossbar unit (A) by inserting fixture mounting screws into set holes 

    on the backplate, then secure it with two rubber pads (E) and two bolt nuts (D).

    

Note: With silicone caulk compound, caulk completely around where the backplate meets with the wall

    surface to prevent water from seeping into the outlet box.

 

5. Install the bulb (not included). Check relamping label at socket area or packaging for maximum wattage allowed.

Sensor

Step 1: Rotate the sensor clockwise or counter-clockwise

            at maximum 90 degree to access the adjustable

            knobs. (See Fig.1)

Step 2: Adjust time and sensitivity, choose the mode you 

            want by turning the knob. (See Fig.2 and Fig.A).

Step 3: Restore the sensor to original position by rotating 

            to the opposite direction. (See Fig.3)

 

 

 

Fig.A

Time

Auto

Off

Mode

Sens

Test

PC

"Time" Knob

"Mode" Knob

"Sens" Knob

Time

Auto

Off

Mode

Sens

Test

PC

Fig.1

Sensor

Fig.3

Fig.2

View 

Fig.A

Adjustable 

Knob

231020

Содержание T0730

Страница 1: ...ground wire is securely connected 7 For general safety and to avoid any possible damage to the sensor be sure the power is switched off before replacing the bulb 8 Compatible with most LED dimmable bu...

Страница 2: ...rew then depending on local code connect it to the house ground wire with the wire connector C Carefully put all of the wires back into the outlet box 4 Attach the backplate of the fixture to the cros...

Страница 3: ...peration only The light will turn on automatically at dusk and turn off at dawn Auto Mode Off Mode Manual Override Manual Override Operation Diagram Turn wall switch OFF ON in 0 5 3 Seconds Turn wall...

Страница 4: ...Motion Motion 150 TROUBLESHOOTING Refer to following information to solve your problems Set the rotary knob in the test mode for testing Night If the light isn t on SYMPTOM DAY NIGHT POSSIBLE CAUSE SO...

Страница 5: ...t suited for the products intended use operation in temperatures outside of the range specified in the instruction manual usage with improper power supply power surges or dips For coastal locations so...

Страница 6: ...ra del artefacto Artefacto Bombilla tipo A de 60 W como m ximo no incluida 231020 INSTRUCCIONES DE ENSAMBLAJE E INSTALACI N Vataje m ximo bombilla de 60 W Temperatura de funcionamiento 22 F 113 F 1 Le...

Страница 7: ...igo local con ctelo al cable de descarga a tierra de la casa con el conector de cable C Vuelva a colocar con cuidado todos los cables en la caja de toma de corriente 4 Adjunte la placa posterior del a...

Страница 8: ...Diagrama de funcionamiento de desactivaci n manual Apague Encienda el interruptor de pared en 0 5 3 segundos Apague Encienda el interruptor de pared en 0 5 3 segundos Fig 4 5 MODO de desactivaci n man...

Страница 9: ...ver los problemas 231020 Coloque la perilla rotatoria en el modo de prueba para comprobar el funcionamiento Noche Si la luz no est encendida S NTOMA D A NOCHE POSIBLE CAUSA SOLUCI N D a La perilla rot...

Страница 10: ...servicio de garant a info vaxcel com 1 800 482 9235 Vaxcel ofrece una garant a de un a o en todos sus productos contra defectos de fabricaci n y acabado a partir de la fecha de env o Adem s Cualquier...

Страница 11: ...W Type A non incluse 231020 INSTRUCTIONS DE MONTAGE ET D INSTALLATION Puissance maximale Ampoule 60 W Temp rature de fonctionnement 30 C 45 C 22 F 113 F 1 Lisez attentivement toutes les instructions...

Страница 12: ...re de la maison l aide du connecteur de fil C Remettez soigneusement tous les fils dans la bo te de sortie 4 Fixez la plaque arri re du luminaire l unit de barre transversale A en ins rant les vis de...

Страница 13: ...ode Auto Mode Off Arr t manuel Sch ma de fonctionnement de la commande Arr t manuel teignez allumez l interrupteur mural en 0 5 3 secondes teignez allumez l interrupteur mural en 0 5 3 secondes Fig 4...

Страница 14: ...sibilit minimale Sensibilit maximale D tecteur Fig 8 Mouvement Mouvement 150 R SOLUTION DES PROBL MES Reportez vous aux informations suivantes pour r soudre vos probl mes 231020 Placer le bouton rotat...

Страница 15: ...tous ses produits contre les d fauts de fabrication et de finition pendant un an compter de la date d exp dition En outre Tout produit dot d un d tecteur de mouvement int gr ou d une cellule photo le...

Отзывы: