background image

OPERATING MANUAL 2000 KMS                                                                               V4.4/20-EN 

Page | 4 

The following applies to all maintenance and repair work:

  

 

It is essential to disconnect the spray gun from the com-
pressed air connection. 

 

Only use original spare parts. 

 

 

The maximum working pressure must not be  exceeded (see 

point 1 "Technical data"). The working pressure must be ad-
justed via a (filter) pressure reducer. 

 

Only use compressed air as energy source 

 

The compressed air connection may only be made via a quick 
coupling. 

 

When working with the pressure cup gun, wear the necessary 
protective clothing, protective goggles, work gloves, ear pro-
tection if necessary and a respirator mask. 

 

If there are leaks in the device or other operating faults, the 
device must be disconnected from the compressed air supply 
immediately and the cause of the fault must be eliminated. 

 

Open fire, sparks or smoking is prohibited. 

 

Beware of flammable materials. 

 

Stone chip and underbody protection remains as well as 
cleaning media must be disposed of in an environmentally 
friendly manner. 

 

The disposal of the compressed air device must be carried 
out according to the valid legal regulations. 

 

6.

 

Installation 

Unscrew the plastic container and fill it with the material to be processed. Then 
screw on the spray gun with the mounted container lid 

hand-tight

. Take care 

not to overtighten the thread! 
Connect the gun to the compressed air supply via the quick coupling. By press-
ing the trigger you put the spray gun into operation. 
The spray pattern can be influenced by the following factors:

 

 

Distance between spray nozzle and object 

 

Angle of the gun to the object 

 

By adjusting the brass spray pipe 
 

7.

 

Maintenance and care 

After each use, disconnect the device from the compressed air supply and thor-
oughly  clean  it.  We  recommend  benzine  or  commercially  available  terpene-
based cleaners. 

Do not use aggressive cleaners!

 Observance of the specified 

maintenance instructions ensures a long service life and trouble-free operation 
for this quality product. 

Содержание 2000 KMS

Страница 1: ...OPERATING MANUAL 2000 KMS V4 4 20 EN Page 1 Spray gun 2000 KMS Art no 20120 ...

Страница 2: ...erefore always keep this operating manual with the spray gun General notices This spray gun was developed for certain applications We explicitly point out that this spray gun must not be modified and or used in a way that does not corre spond to its intended use Content 1 Technical data 3 2 Extent of delivery 3 3 Intended use 3 4 Features 3 5 Safety instructions 3 6 Installation 4 7 Maintenance an...

Страница 3: ...e Venturi effect For this purpose an air stream is used which accelerates when the air nozzle flows through and thus generates negative pressure in the adjoining riser pipe The spray mass is thereby sucked in and sprayed out via the nozzle by the air flow 5 Safety instructions Protect yourself and the environment by taking appropriate precautions against the risk of accidents and observe the follo...

Страница 4: ... Stone chip and underbody protection remains as well as cleaning media must be disposed of in an environmentally friendly manner The disposal of the compressed air device must be carried out according to the valid legal regulations 6 Installation Unscrew the plastic container and fill it with the material to be processed Then screw on the spray gun with the mounted container lid hand tight Take ca...

Страница 5: ... pipe or ventilation hole dirty Solution Clean parts Gun does not spray any material Possible cause Riser pipe brass spray pipe clogged Solution Clean clogged parts Air escapes from the spray nozzle even though the trigger is in its initial position Possible cause Valve bolt is jammed Solution Pour oil onto the valve bolt and or into the compressed air intake Operate the trigger several times 10 W...

Страница 6: ...e your sales representative is at your side or contact the fol lowing address Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach Germany Telephone 49 0 2774 80069 0 E Mail info vaupel gmbh de Internet www vaupel gmbh de Notice We reserve the right to make technical changes Illustrations may differ from the original We assume no liability for printing errors ...

Страница 7: ... with the above EC Di rectives under the general responsibility of Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete The following harmonised standard has been applied DIN EN ISO 12100 Sicherheit von Maschinen Allgemeine Gestaltungsleit sätze Risikobeurteilung und Risikominderung The operating manual belonging to the ...

Страница 8: ...ng for valve 9 60 4100 062 O ring 8 x 1 mm 10 30 1120 002 Locking screw 11 30 1422 008 Air nozzle 2 5 mm 12 30 3410 004 Lock nut optional 13 30 1129 001 Brass spray pipe 2900 MS 14 10 1126 003 fixing screw 15 40 4104 015 Adapter 2000 16 10 2150 001 Aluminium plate 2000 Ø 50 mm 17 50 3100 003 Washer Ø 50 mm 18 30 1433 033 Straight screw on fitting 10 19 10 4109 024 Rising pipe PE natural 100 mm 20 ...