background image

 

User manual 

 

 

 

 

 

 

 

Laser Moonstar MK II

Содержание Laser Moonstar MK II

Страница 1: ...User manual Laser Moonstar MK II ...

Страница 2: ...TRUCTIONS 8 5 BEFORE OPERATION 9 5 1 Unpacking Instructions 9 5 2 What is included 9 5 3 Power Supply 9 5 4 DMX 512 connection between fixtures 10 5 4 1 Occupation of the XLR connection 10 5 4 2 Building a serial DMX chain 10 6 Proper Laser Set Up Usage 11 6 1 Rigging the Fixture 12 7 PRODUCT OVERVIEW 13 7 1 Front Panel 13 7 2 Rear Panel 14 8 CONTROL FUNCTION 14 8 1 Operating Mode 15 8 2 OPERATION...

Страница 3: ... a location with high humidity or lots of dust Containers with water should not be placed on the set Keep away from sources of hum and noise Such as transformer motor tuner TV set and amplifier To avoid placing on un stable location Select a level and stable location to avoid vibration Do not use chemicals or volatile liquids for cleaning Use a clean dry cloth to wipe off the dust or a wet soft cl...

Страница 4: ...mation to protect people from laser incident or damage Caution Prevent damage or injury from incorrect operation Laser Laser safety warming labels Recycle To protect the environment recycle packing material wherever possible Indoor The projector is for indoor use only IP20 Use only in dry locations Keep this device away from rain and moisture excessive heat humidity and dust Do not allow contact w...

Страница 5: ...ASER SAFETY AND OPERATING INSTRUCTIONS STOP AND READ ALL LASER SAFETY DATA Laser light is different from any other light source witch you may be familiar The light from this product can potentially cause eyes injury if not set up and used properly Laser light is thousands of times more concentrated than light from any other kind of light source This concentration of light power can cause instant e...

Страница 6: ...a federal offense Never point un terminated laser beams into the sky Do not expose the output optic aperture to cleaning chemicals Do not use laser if the laser appears to be emitting only one or two beams Do not use laser if housing is damaged or open or if optics appear damaged in any way Never open the laser housing The high laser power levels inside of the protective housing can start fires bu...

Страница 7: ... typical Green Laser Medium DPSS Nd YVO4 532nm Beam Diameter 5mm at aperture Pulse Data All pulses 4Hz 0 25sec Divergence each beam 2 mrad Divergence total light 160 degrees Cooling Fan Cooling Laser Power Red 100mW Green 40mW 3 2 LASER COMPLIANCE STATEMENT This laser product complies with EN 60825 1 1994 A1 2002 A2 2001 COTT ...

Страница 8: ...d after installing the device Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when the devise is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord It is essential to connect the yellow green conductor to earth The el...

Страница 9: ...dling Save the package and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing 5 2 What is included The carton or flight case contain following items NAME QTY Laser Light 1 PCS KEYs for key switch 2 PCS Power Cord 1 PCS USER MANUAL 1 PCS 5 3 Power Supply To determine the power require...

Страница 10: ...rallel Only use a shielded twisted pair cable designed for 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another 5 4 1 Occupation of the XLR connection CAUTION At the laser fixture the DMX cable has to terminate with a terminator Solder a 120 Ohm resistor between Signal and Signal into a 3 pin XLR plug and plug and plug it in the DMX output ...

Страница 11: ...high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system The DXM output and input connectors are pass through to maintain the DMX circuit when power is disconnected to the unit Each fixture needs to have a DMX address to receive the data from the controller The DMX address number which could be read from rear panel...

Страница 12: ...main attachment fails Make sure the area below the installation place is free from unwanted persons during rigging de rigging and servicing The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safe...

Страница 13: ...for the user to follow the safety instructions and warning notes written in this manual The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device 7 1 Front Panel NO NAME FUNCTION 1 LED Output Effekt Output LED 2 Laser output Laser output Lense 3 Bracket To mount the item ...

Страница 14: ...n and off the laser 11 Safety Eye Used to attach a safety cable when the fixture is rigged Check more details in RIGGING 12 Power Plug AC 100 240V 50 60Hz 8 CONTROL FUNCTION Regular breaks during operation are essential to maximize the life of this device as it is not designed for continual use Do not switch the unit on and off in short time intervals Always unplug the unit when it is not used for...

Страница 15: ...el is very easy to set and change the operating mode of laser After every resetting and saved the new mode information will be shown on LCD monitor at next power on Mode Option to choose the operating mode of laser Confirmation to confirm the laser to show the present mode at the next operation UP DOWN to change operating mode parameter or DMX address 8 2 OPERATION Attention In preprogrammed stand...

Страница 16: ... alone laser show that you are going to choose is flashing Press FUNC to change stand alone laser show you will have 3 different stand alone preprogrammed laser show Their DISPLAY and EFFECT are listed below 8 4 Sound Activated Sensitivity Setting In the MODE setting press ENTER to confirm Sou Sound Activated Mode the setting manual goes into Sound Activated Sensitivity Setting LED display S 0 S 9...

Страница 17: ...ast slow 3 SR0 SR9 LED Strobe frequency fast slow RDE mode is LED RAINBOW FADE FROM COLOR TO COLOR NO DISPALY DESCRIPTION 1 SP 0 SP 9 LED RAINBOW FADE SPEED 0 100 8 6 DMX MODE Press FUNC to enter MODE OPTION Till to LED panel shows 001 Press ENTER to confirm the setting The laser is working in DMX MODE With help of UP DOWN button it could be easily change the DMX address of the laser 8 7 MASTER SL...

Страница 18: ...18 22 9 DMX Chart ...

Страница 19: ...19 22 ...

Страница 20: ...20 22 ...

Страница 21: ...ontrol Audio Sound Activated Laser Power 100mW 650nm Red CW 40mW 532nm Green CW Laser Classification Class 3B Laser Safety Standard EN60825 1 2007 Condition Temperature 10 40 DMX Connections 3 pins XLR Male Female DMX Channels 12 channels Measurement Siehe unteres Bild N Weight 1 7Kg LED Power 3W 3W 3W ...

Страница 22: ...n is subject to change without prior notice The availability of particular products may vary by region Please check with the dealer Importer B K Braun GmbH Industriestraße 1 D 76307 Karlsbad www bkbraun com info bkbraun com ...