WARNING!
Risk of burns at the surface and inside of the device
The surface and the inner parts of the device can become very hot during opera-
tion.
After switching off the device wait for at least 15 minutes before you start any
maintenance activities.
1.
Make sure that the device is turned off, disconnected from the mains and completely
cooled down.
2.
Move the device in a horizontal position.
3.
Carefully unscrew the star knob screw on the rear panel completely. Slide the upper
housing cover all the way back.
4.
Loosen the knurled screw that connects the fixing ring to the housing. A long nose pliers
may be handy on this.
5.
Remove the fixing ring backwards. The lens can then be removed.
6.
Insert the new lens. Pay attention to the retaining pin on the right side of the housing.
Procedure
Maintenance
24
650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel
theatre spotlight