background image

Only the following illuminants are permitted:

Model

Base

Power consumption

Theater Spot 650/1000 Antihalo

Base GX9.5

650 W
1000 W

Theater Spot 650/1000 Fresnel

Base GX9.5

650 W
1000 W

Theater Spot 650/1000 PC

Base GX9.5

650 W
1000 W

Theater Spot 300/500 Antihalo

Base GY9.5

300 W
500 W

Theater Spot 300/500 Fresnel

Base GY9.5

300 W
500 W

Observe the safety instructions of the illuminant manufacturer.

Notes on the illuminant

Maintenance

 

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel

21

theatre spotlight

Содержание 650 Antihalo

Страница 1: ...650 1000 Antihalo 650 1000 Fresnel 650 1000 PC 300 500 Antihalo 300 500 Fresnel theatre spotlight User manual...

Страница 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 28 12 2017 ID 335412 335413 335424 335427 390866...

Страница 3: ...nstructions 10 3 Features 15 4 Connections and controls 16 5 Maintenance 18 5 1 Installing replacing the illuminant 18 5 2 Changing the lens 23 6 Technical specifications 26 7 Cleaning 29 8 Protecting...

Страница 4: ...4 650 1000 Antihalo 650 1000 Fresnel 650 1000 PC 300 500 Antihalo 300 500 Fresnel theatre spotlight...

Страница 5: ...ual for future reference Make sure that it is available to all those using the device If you sell the unit please make sure that the buyer also receives this manual Our products are subject to a proce...

Страница 6: ...ctronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For personal consultatio...

Страница 7: ...hted by an arrow Example 1 Switch on the device 2 Press Auto Automatic operation is started 3 Switch off the device 1 3 Symbols and signal words In this section you will find an overview of the meanin...

Страница 8: ...sible dangerous situation that can result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in...

Страница 9: ...Warning signs Type of danger Warning danger zone General information 650 1000 Antihalo 650 1000 Fresnel 650 1000 PC 300 500 Antihalo 300 500 Fresnel 9 theatre spotlight...

Страница 10: ...t in personal injury or property damage No liability will be assumed for damages resulting from improper use This device may be used only by persons with sufficient physical sensorial and intellectual...

Страница 11: ...devices DANGER Dangerous voltages The rewiring exchanging of light bulbs and general electrical maintenance of this product should only be carried out by electrical specialists Failure to follow thes...

Страница 12: ...before connecting the device again Do not use the device if covers protectors or optical components are missing or damaged DANGER Electric shock caused by short circuit Do not modify the mains cable...

Страница 13: ...ecome very hot during opera tion After switching off the device wait for at least 15 minutes before you start any maintenance activities NOTICE Risk of fire Do not block areas of ventilation Do not in...

Страница 14: ...tage AC outlet matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly inj...

Страница 15: ...00 Fresnel are suitable for halogen stage lights with GY9 5 base 230 V maximum power consumption 500 W not included n Manually adjustable zoom range from 10 to 40 n Model 650 1000 Antihalo model 300 5...

Страница 16: ...4 Connections and controls Rear panel Connections and controls 16 650 1000 Antihalo 650 1000 Fresnel 650 1000 PC 300 500 Antihalo 300 500 Fresnel theatre spotlight...

Страница 17: ...racket 4 Power cord 5 Locking screw for focus Loosen the screw and position the slider for optimum illumination 6 Retaining bracket 7 Holder for barn doors colour films or filters Connections and cont...

Страница 18: ...esent Completely disconnect the device from the power supply before you open or remove covers Mount all covers and attach them firmly before connecting the device again Do not use the device if covers...

Страница 19: ...e you start any maintenance activities NOTICE Possible damages due to dirt or finger prints Due to the high temperatures even smallest pieces of dirt on the bulb can destroy the lamp when it is turned...

Страница 20: ...use the device with a lamp other than those specified in this manual can result in severe damages to the device Only use a lamp of the specified type Maintenance 20 650 1000 Antihalo 650 1000 Fresnel...

Страница 21: ...5 650 W 1000 W Theater Spot 650 1000 PC Base GX9 5 650 W 1000 W Theater Spot 300 500 Antihalo Base GY9 5 300 W 500 W Theater Spot 300 500 Fresnel Base GY9 5 300 W 500 W Observe the safety instructions...

Страница 22: ...l the old illuminant out of the socket on the bottom of the unit Be careful not to touch the hollow mirror behind the socket 5 Insert the new illuminant firmly into the socket Check the secure fit 6 S...

Страница 23: ...disconnect the device from the power supply before you open or remove covers Mount all covers and attach them firmly before connecting the device again Do not use the device if covers protectors or o...

Страница 24: ...2 Move the device in a horizontal position 3 Carefully unscrew the star knob screw on the rear panel completely Slide the upper housing cover all the way back 4 Loosen the knurled screw that connects...

Страница 25: ...k the lens for firm fit 8 Slide the upper housing cover all the way to the front Tighten the star knob screw completely 9 Check that the upper housing cover is properly seated Maintenance 650 1000 Ant...

Страница 26: ...plug e g item no 324015 Barn door e g item no 335429 Zoom range 10 40 Power consumption depends on the inserted illuminant Operating supply voltage 230 V 50 Hz Dimensions W H D 325 280 520 mm Weight...

Страница 27: ...e g item no 324015 Barn door e g item no 335429 Zoom range 10 40 Power consumption depends on the inserted illuminant Operating supply voltage 230 V 50 Hz Dimensions W H D 270 220 370 mm Weight 5 8 kg...

Страница 28: ...e g item no 324015 Barn door e g item no 335419 Zoom range 10 40 Power consumption depends on the inserted illuminant Operating supply voltage 230 V 50 Hz Dimensions W H D 255 215 390 mm Weight 4 6 k...

Страница 29: ...Clean with a soft cloth using our lamp and lens cleaner item no 280122 n Always dry the parts carefully The fan grids of the device must be cleaned on a regular basis to remove dust and dirt Before cl...

Страница 30: ...e packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE Do not dispose with your normal household waste Dispose of this device through an approved...

Страница 31: ......

Страница 32: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...

Отзывы: