Always pull out the plug and drain the receiver once you have completed your work 
(figures 10-11) 

8  MAINTENANCE 

 

Before carrying out any operation, always pull out the plug and drain the receiver 
completely (figures 10-11) 

 

Check that all screws ( in particular those of the head of the unit) are tightly drawn up. The 
check must be carried out prior to the first compressor starting. 

 

After loosening any safety screws (fig. 12a), clean the intake filter according to the type of 
working environment and at least every 100hours (figures 12b-12c). if necessary, replace 
the filter element (clogging of the filter reduces compressor performance and an inefficient 
filter causes increased wear). 

 

For lubricated models, replace the oil after the first 100 hours of operation and every 300 
hours sebsequently (figures 13a-13b-13c). remember to check the oil level at regular 
intervals. 
Use API CC/SC SAE 40. (for cold climates, API CC/SC SAE 20 is recommended). Never 
mix different grade oils. If the oil changes color (whiish = presence of water, dark = 
overheated), it is good practice to replace the oil immediately. 

 

Periodically (or after working with the compressor for more than an hour), drain the 
condensate that forms inside the receiver (fig. 11) due to the humidity in the air. This 
protects the receiver from corrosion and does not restrict its capacity. 

 

Spent oil (lubricated models) and condensate MUST BE DISPOSED OF in accordance 
with environmental protection regulations and current legislation. 

Table 1 

– Maintenance 

Function 

After the first 100 hours 

Every 100 hours 

Every 300 hours 

Cleaning of intake filter 
and / or substitution of 
filtering element 

 

 

 

Change of oil* 

 

 

 

Tightening of head 
tension rods 

The check must be carried out prior to the first compressor 
starting 

Draining tank 
concensate 

Periodically and at the end of work. 

* For lubricated models only 

9  TECHNICAL DETAILS 

Rated voltage 

220-240 V~ 

Rated frequency 

 

50 Hz 

Rated Power 

1500W / 2HP 

Rotation speed 

2850 min

-1

 

Rated Pressure 

8 bar / 116 PSI 

Tank capacity 

24 l 

Air debit (capacity) 

222 l/min 

Weight 

25 kg 

Cylinder 

Lubricated 

Yes  

 

 

Содержание Powerplus POWX1735

Страница 1: ...Working area 3 5 2 Electrical safety 3 5 3 Personal safety 3 5 4 Power tool use and care 4 5 5 Service 4 6 SPECIFIC SAFETY WARNINGS 4 6 1 Do s 5 6 2 Don ts 5 6 3 Things you should know 6 7 START UP A...

Страница 2: ...packaging materials Remove remaining packing and package inserts if included Check that the package contents are complete Check the appliance the power cord the power plug and all accessories for tra...

Страница 3: ...sk of an electric shock Avoid body contact with earthed surfaces such as pipes radiators kitchen ranges and refrigerators There is an increased risk of an electric shock if your body is earthed Do not...

Страница 4: ...ach of children and do not allow people who are not familiar with the power tool or these instructions to operate it Power tools are potentially dangerous in the hands of untrained users Maintain powe...

Страница 5: ...dy Always wear safety goggles to protect your eyes against flying objects that maybe lifted by the jet of air Never direct the jet of liquids sprayed by tools connected to the compressor towards the c...

Страница 6: ...et fig 6 checking the the button of the pressure switch located on the compressor is in the OFF O position For lubricated models check the oil level using the rod included in the oil fuel plug figures...

Страница 7: ...PI CC SC SAE 20 is recommended Never mix different grade oils If the oil changes color whiish presence of water dark overheated it is good practice to replace the oil immediately Periodically or after...

Страница 8: ...d the special rubber disk replace if worn Reassemble and tighten carefully figures 14a 14b Reduction of performance Frequent start up Low pressure values Excessive performance request check for any le...

Страница 9: ...h the device is not suitable incompetent usage e g not following the instructions given in the manual inexpert assembly lightning strike erroneus net voltage This list is not exhaustive Acceptance of...

Страница 10: ...he apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2004 108 EC 2006 42 EC 2000 14 EC Annex VI LwA 91dB A 94dB A Tes...

Отзывы: