background image

 

POWX07590 

EN

 

Copyright © 2019 VARO 

P a g e

 | 

12

 

www.varo.com 

 

Push the workpiece evenly towards the back and saw in a single process. Make sure that 
the saw Is not overloaded. 

 

Use the red button 0 on the On / Off switch (1) to switch the unit off if you are not going to 
continue working immediately. 

9.7 

Dust extraction connection 

The dust extraction connection (5) is located at the rear of the saw.  A dust collection system 
can be attached to this port to aid the removal of sawdust from the work area. 

10 CLEANING AND MAINTENANCE 

10.1 

Cleaning and maintenance overview 

Prior to each use 

What? 

How? 

Check the saw blade to ensure it is 
correctly positioned and fixed in place. 

Changing the saw blade 

Check the saw blade protector box for wood 
chippings/saw dust Remove chippings if 
necessary. 

Use compressed air to blast the 
chippings/dust out or use a brush. 

Check that the gap between the saw blade 
and the cleaving wedge is set to 3 to 5 mm; 
correct if necessary. 

Adjusting the cleaving wedge 

Check the connection cable for any signs of 
damage 

Conduct a visual inspection and have the 
cable replaced by an electrician if 
necessary. 

Regularly and according to operating conditions 
What?  

How? 

Screw connections 

Check all screw connections and tighten if 
necessary. 

Clean the ventilation slots on the motor to 
remove dust 

Use a vacuum or a brush  to remove the 
chippings/dust. 

10.2 

Cleaning the device 

Risk of electric shock! Never splash with water or expose to water. Never 
use detergents or solvents to clean. These may cause irreparable damage 
to the unit The plastic pieces may be corroded by the chemicals. 

Careful treatment and regular cleaning will ensure that the unit remains functional and 
performs well for a long time. 

 

Remove dirt with a brush. 

 

Wipe the tool with a damp cloth. 

 

Keep ventilation slots clean and free of dust 

10.3 

Unit maintenance 

Risk of injury! Before conducting any maintenance work make sure the 
device is unplugged (disconnect the power supply). 

Risk of injury! Shortly after sawing, the saw blade may be very hot. Allow a 
hot blade to cool down. Never dean a hot saw blade with flammable liquids. 

A still saw blade can cause injury! Use gloves to change the saw blade. 

Содержание POWER PLUS POWX07590

Страница 1: ...procedures warnings 6 6 3 Kickback causes and related warnings 6 6 4 Table saw operating procedure warnings 7 7 SAFETY EQUIPMENT 7 7 1 Cleaving wedge 7 7 2 Saw blade protector 7 7 3 Push stick 7 8 UN...

Страница 2: ...10 9 4 Setting the cutting height Fig 6 11 9 5 Setting the saw blade angle Fig 7 11 9 6 Sawing 11 9 7 Dust extraction connection 12 10 CLEANING AND MAINTENANCE 12 10 1 Cleaning and maintenance overvi...

Страница 3: ...rgency stop 2 Saw blade height and tilt angle adjustment crank 3 Locking knob of the saw blade rotary knob 4 Cut angle indicator 5 Dust extraction connection 6 Table extension 7 Saw blade guard 8 Clea...

Страница 4: ...ngs for example in the presence of inflammable liquids gases or dust Power tools create sparks that may ignite the dust or fumes Keep children and bystanders at a distance when operating a power tool...

Страница 5: ...g such devices can reduce dust related hazards 5 4 Power tool use and care Do not expect the power tool to do more than it was designed to do Use the correct power tool for what you want to do A power...

Страница 6: ...Never reach around or over a rotating saw blade Provide auxiliary workpiece support to the rear and or sides of the saw table for long and or wide workpieces to keep them level Feed workpiece at an e...

Страница 7: ...efore the table saw is turned on Always use saw blades with correct size and shape diamond versus round of arbour holes Never use damaged or incorrect saw blade mounting means such as flanges saw blad...

Страница 8: ...wo bolts through the aligned mounting holes of the leg d and brace e attach washers spring washers and nut to the bolts and tighten two nuts Note the auxiliary supports must be mounted at the back of...

Страница 9: ...is used again Check to make sure the device is in safe operating condition Check to make sure there are no visible defects Check to make sure all device components are correctly mounted Check to make...

Страница 10: ...h stop plate C and then retighten adjusting screws B 9 3 3 Setting the stop rail of the parallel stop The stop rail can be removed and repositioned after both wing nuts have been loosened High stop ed...

Страница 11: ...perating saw blade Only adjust the blade angle when the saw blade is at a standstill Loosen the fixing screw 3 Set the required angle of tilt The set tilt angle can be read from the scale 4 Tighten th...

Страница 12: ...k the connection cable for any signs of damage Conduct a visual inspection and have the cable replaced by an electrician if necessary Regularly and according to operating conditions What How Screw con...

Страница 13: ...Bring the saw blade into the upper position Remove the saw blade protector Remove the table surface Loosen the screw A slightly with a suitable combination spanner until the cleaving wedge 8 is relea...

Страница 14: ...ore information at the number 00 32 3 292 92 90 Any transportation costs shall always be borne by the customer unless agreed otherwise in writing At the same time no claim can be made on the warranty...

Страница 15: ...del POWX07590 is in conformity with the essential requirements and other relevant provisions of the applicable European Directives based on the application of European harmonized standards Any unautho...

Отзывы: