Varmeteknikk AS

   

Phone  +47 23 37 55 00       August 2020 V2

                      

25 

    

Spare parts for MB 35 

– 150 kW 

 

 

 

                                                                             

 Antall  pr. kjele

 

    Gjenstand 

     Artikkel nr.         35 kW 

        45 kW 

       60 kW 

        75 kW 

        90 kW  

     105 kW 

      120 kW 

     140 kW 

      150 kW 

Heating element      5 kW/230 V 

6613 0001-K 

 

 

 

 

 

 

 

Heating element    10 kW/230 V 

6672 0242-A 

 

 

 

 

Heating element    15 kW/230 V 

6672 0242-D 

 

 

 

 

Heating element    20 kW/230 V 

6672 0242-G 

 

 

Heating element 22,5 kW/230 V 

6672 0242-Q 

 

 

 

 

 

 

Element gasket 

2152 0022-4 

Temp.controller  7-steps 

901 310 

Sensor for temp.controller 

200 232 

On-/Off-switch 

6672 0235-3 

Safety temp. limiter 

6672 0235-1 

    

230 V     400 V 

230 V 

400 V 

230 V  400 V  230 V  400 V  230 V  400 V  230 V  400 V  230 V  400 V  230 V  400 V 

230 V 

400 V 

Contactor   AF09 

     41 175 00 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contactor   AF12 

     41 175 16 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contactor   AF16 

     41 175 32 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contactor   AF26 

     41 175 48 

 

 

 

 

 

 

Contactor   AF30 

     41 175 56 

 

 

 

 

 

 

 

 

 

 

 

 

Contactor   AF40 

     41 175 75 

 

 

 

 

 

 

Contactor   AF52 

     41 175 80 

 

 

 

 

 

 

 

 

 

 

 

Contactor   AF65 

     41 175 86 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contactor   AF80 

     41 175 92 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contactor   AF116 

     41 176 10 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contactor   AF140 

     41 177 79 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse 10 A 

6672 0235-27 

Switch  MS132/10 

     43 640 79 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch  MS132/16 

     43 640 80 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch  MS132/20 

     43 640 81 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch  MS132/32 

     43 640 83 

 

 

 

 

 

 

 

 

 

 

Switch  XT1N-40 

      067 412 

 

 

 

 

 

 

 

 

 

 

 

Switch  XT1N-50 

      067 413 

 

 

 

 

 

 

 

 

 

 

 

Switch  XT1N-63 

      067 414      

 

 

 

 

 

 

 

 

 

Switch  XT1N-80 

      067 415  

 

 

 

 

 

 

 

 

 

 

Switch  XT1N-100 

      067 416 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch  XT1N-125 

      067 417 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch  XT1N-160 

      067 418 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sec transformer     

      200 018 

Power transformer    100/5 A 

    6672 0235-50 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power transformer    200/5 A  

    6672 0235-51 

 

 

 

 

 

 

 

 

 

 

Power transformer    300/5 A 

    6672 0235-53 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power transformer    400/5 A 

    6672 0235-54 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                                                                                                                                                                                                                                           
 

Cooke Industries - Phone: +64 9 579 2185   Email: [email protected]   Web: www.cookeindustries.co.nz

Содержание MB 105

Страница 1: ...Operation instructions for MB 35 150 kW August 2020 Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web www cookeindustries co nz...

Страница 2: ...Varmeteknikk AS Phone 47 23 37 55 00 August 2020 V2 1 Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web www cookeindustries co nz...

Страница 3: ...ls for SD systems 10 Menus 11 Power control connection 12 Maintenance 14 Troubleshooting 15 Technical specifications 16 Dimensions 17 Energy labelling 18 Control circuit diagram 19 Main circuit form 2...

Страница 4: ...ere should be no shut off between the boiler and safety valves Safety valves and expansion vessels must be dimensioned in accordance with the system s boiler performance Boilers below 100 kW must have...

Страница 5: ...pressing the button Then the E button to save new value The step time is set to 40 seconds and should not be set lower as shorter step time will lead to unnecessary wear on the contactors It is norma...

Страница 6: ...ps The step time is changed as follows With a press of the menu button the menu for Step Step time appears With a press of the button the display will now show Step 7 7 Step time 40s Step lim 7 7 Step...

Страница 7: ...outdoor sensor is connected the set temperature will be adapted to the outdoor temperature The slope curve determines how much the boiler temperature should change in f h t change in outdoor temperat...

Страница 8: ...outdoor temperature Boiler temperature Boiler temperature Outdoor temperature Outdoor temperature Curve 22 Curve 40 Curve 50 Curve 60 Parallel Curve Parallell 0 Parallell 20 Parallell 20 Cooke Indust...

Страница 9: ...the inclination curve can also be adjusted By choosing a steeper curve the trip temperature can be further increased Adjustment of the slope is made in the service menu see page 12 In the menu slope t...

Страница 10: ...Power again With external temperature control switched on the display shows TempE 47 0 75 C Power 60kW NB With external temperature control the set temperature on the controller will function as a max...

Страница 11: ...tion to temperature and power control with 0 10 V signal the boiler is also prepared for power regulation ie the boiler can be controlled so that it has the power that is available at any given time b...

Страница 12: ...rature Adjustment limitation of max available steps Adjustment of step time NB Short step time will reduce the lifetime of the contactors Service menus For access to service menu press and hold arrow...

Страница 13: ...tion has limited the boiler to a certain power you get to a point where a step will constantly switch on and off To prevent the boiler from switching on and off the power stage a certain power margin...

Страница 14: ...you will have access to setting the current margin With the buttons the current margin is set to the calculated value 0 6 The new value is saved by press the E button See also page 12 Current marg 0...

Страница 15: ...wear and should be checked carefully or replaced Worn contactors can burn fixed and cause great damage Electrical connections All connections on busbars power switches contactors and elements are tigh...

Страница 16: ...temp limiter has tripped Reset Safety temp limiter STB on front panel Temp 30 0 80 C Alarm Power Main switch off or broken fuses Check switch board fuses Replace if required Little heat from boiler T...

Страница 17: ...40 60 90 110 130 150 DN 65 16 1 75 6 5 0 47 28 155 Technical data for 400V boilers Model kW Amp Power steps Connection flange Connection exp drain Water volume liter Q t 20 C m h v m s dP mm Vs Weight...

Страница 18: ...Varmeteknikk AS Phone 47 23 37 55 00 August 2020 V2 17 Dimensions All dimensions in mm Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web www cookeindustries co nz...

Страница 19: ...del MB 35 MB 45 MB 60 Energy class D D D Nominel heating power Prated 35 45 60 Season heating efficiency s 37 37 37 Energy consumption year in kWh Noice level dB 53 53 53 Cooke Industries Phone 64 9 5...

Страница 20: ...oltage 230V 50Hz sensor Start stop control Operation Failure Remote Out door temp sensor Remote control Safety temp limiter STB Power contr 0 10V Temp contr 0 10V 0 Power ind 10V Temp ind 10V Pre set...

Страница 21: ...5 E6 E7 E1 E2 E3 kW 35 E1 5 E2 10 E3 20 kW 45 60 75 E1 5 10 10 E2 15 15 20 E3 15 15 22 5 E4 10 20 22 5 kW 90 105 120 E1 15 15 15 E2 15 15 15 E3 10 15 22 5 E4 20 20 22 5 E5 15 20 22 5 E6 15 20 22 5 kW...

Страница 22: ...circuit MB 400 V kW 35 E1 5 E2 10 E3 20 kW 45 60 75 E1 5 10 10 E2 15 15 20 E3 15 15 22 5 E4 10 20 22 5 kW 90 105 120 E1 15 15 15 E2 15 15 15 E3 10 15 22 5 E4 20 20 22 5 E5 15 20 22 5 E6 15 20 22 5 kW...

Страница 23: ...K3 K4 K5 K6 K7 K8 0 0 Alarm Operation Temp sensor Transformer for power indication Current transformers 10V power control 10V temp control Outdoor sensor Power limitation Signal converter in out contr...

Страница 24: ...2090 300 24 MB 4090 200 28 MB 2105 300 24 MB 4105 200 28 MB 2120 400 32 MB 4120 200 28 MB 2140 400 32 MB 4140 200 28 MB 2150 400 32 MB 4150 300 42 Sensor resistance Boiler sensor NTC22k o C 0 10 20 30...

Страница 25: ...Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web www cookeindustries co nz...

Страница 26: ...AF26 41 175 48 1 1 2 1 1 1 1 2 2 2 1 1 Contactor AF30 41 175 56 1 1 1 1 1 1 Contactor AF40 41 175 75 1 1 1 1 1 1 1 1 1 1 1 1 Contactor AF52 41 175 80 1 2 1 1 1 3 3 Contactor AF65 41 175 86 Contactor A...

Страница 27: ...Varmeteknikk AS Phone 47 23 37 55 00 August 2020 V2 26 Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web www cookeindustries co nz...

Страница 28: ...Varmeteknikk AS Phone 47 23 37 55 00 August 2020 V2 27 Notes Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web www cookeindustries co nz...

Страница 29: ...7 23 37 55 00 August 2020 V2 28 VarmeteVarmeteknikk AS PO Box 6 Alnabru NO 0614 Oslo Tlf 23 37 55 00 post varmeteknikk no Cooke Industries Phone 64 9 579 2185 Email sales cookeindustries co nz Web www...

Отзывы: