General information
9
Värmebaronen Vedolux 55
Technical data
Weight
empty
1049 lb
full of water
1592 lb
Water volume
65 gal
Fuel
wood
length
19.7 in
moisture content
16
±
8 %
Wood store
volume
43.6 gal
depth:
22.6 in
Filling hatch
w x h
11 x 9 in
Burning time
full wood store
2-3 h
Power
nominal
195.5 kBTU/h
Pressure
design
21.8 Psi
test
31.2 Psi
Temperature
max.
230 °F
Chimney requirements:
Straight steel chimney with
∅
3.9 in., recommended height 0 - 98.4 in.
Straight steel chimney with
∅
4.9 in., recommended height 0 - 275.6 in.
Straight steel chimney with
∅
6.3 in., recommended height 0 -
∞
.
Flue gas temperature
nominal output
310 °F
Flue gas flow rate
0.11 lb/s
Operation, natural ventilation/fan
with flue gas fan
Condensing/non-condensing
non-condensing
Positive/negative pressure at flue gas outlet
negative pressure
Pressure drop, water side
q = 820 gal/h,
∆
t = 50°F
0.15
4.22
Psi
inH
2
O
q = 423 gal/h,
∆
t = 68°F
0.03
0.76
Psi
inH
2
O
Return temperature
min.
≥
120 °F
Temperature setting
200 °F
Accumulator volume
min.
660 gal
Cooling coil, incoming cold water
connection pressure
temperature
≥
29
<59
Psi
°F
Boiler class in accordance with EN 303-5
Class 3
Voltage
115 V~ +10/-15%, 60 Hz
Current consumption
max.
0.46 A
Power consumption
operation, max.
50 W
(without any additional appliances connected)
standby
0 W
IP class
IPx1
Ambient temperature
during operation
0 - 86 °F
Noise level during operation
50 dB
Manufactured to
PED 97/23/EC article 3.3