Installation

11

Värmebaronen Vedolux 55

  Installation must take place according to 

existing regulations and standards.

•  The boiler must be placed indoors in a boiler 

room designed to meet the existing standard.

•  The installation site must withstand the 

weight of the boiler, the accumulator tank and 
any chimney.

The boiler may be loaded with maximum 
220 lb of the chimney's weight vertically 
downwards.

•  There must be a fresh air intake. Any 

mechanical ventilation in the room must not 
create any negative pressure that disturbs 
the operation of the boiler. The boiler room's 
fresh air intake must have an area at least 
as large as that of the chimney and it must 
be designed so that it cannot be closed by 
mistake.

•  The existing standards for minimum distance 

to combustible material must be met.

The minimum distance for removing the flue 
gas fan = minimum 11 in free space behind 
the flue gas fan.
Ensure that the provisions for sweeping meet 
the existing regulations.

•  Adjust the foot bolts so that the boiler is 

horizontal.

•  The flue pipe must be connected according to 

existing standards.

It is important for all connection points and 
flues not to leak dust and gas.
If the boiler is connected higher up the 
chimney than a previous boiler was 
connected, the lower, inactive part must be 
filled.

•  The boiler must be connected to an open or 

closed expansion system.

•  The boiler must be connected to an 

accumulator system. The installation must 
have accumulator control.

•  A temperature limiter, thermal valve (STW), 

must be fitted.

•  No work must take place on the boiler's cover 

plates as it can damage the boiler's electrical 
equipment.

•  The boiler is not designed for oxygenated 

water. Hard, calcareous water is not suitable 
in a plumbing and heating context.

If you have your own well, the water quality 
must be checked so that it does not cause 
damage. Copper in the pipes must not be 
subjected to abnormally aggressive water. 
A water analysis will give you the necessary 
information. If the water quality is poor, 
a water filter must be installed.

•  The turbulators and the draught damper can 

be used to adjust the flue gas temperature if 
there is a risk of condensation in the chimney.

•  A chimney-sweep must be contacted before a 

different type of fuel is used.

•  Contact the local authority regarding 

restrictions on burning solid fuel in a densely 
built-up area.

Installation

Содержание Vedolux 55

Страница 1: ...13 0 9 11 T H L n o x x x x r e v 0 Installation and maintenance Vedolux 55...

Страница 2: ...2 V rmebaronen Vedolux 55...

Страница 3: ...oiler from cold Installation 15 System check Instructions to customer About wood firing About wood handling wood and storage FOR THE USER Starting the boiler 16 Starting First firing Firing starting F...

Страница 4: ...4 V rmebaronen Vedolux 55 Serial number Installation date Plumber Phone Electrician Phone Other To be completed when the Vedolux 55 is installed...

Страница 5: ...the chimney so that there are no gas and dust leaks Thermal valve STW has been fitted Expansion tank volume correctly dimensioned Pay attention to prepressurisation in a closed tank System has been f...

Страница 6: ...fan causes the flames to move downwards through the grate The gases remaining are combusted in the ceramics The hot flue gases then continue through the boiler s flues where the heat is absorbed and...

Страница 7: ...le material on the boiler or flue pipe Be careful if you need to open the boiler s hatches during operation If the hatch is opened too fast flames may shoot out Read these instructions carefully befor...

Страница 8: ...h hatch with draught hatch 14 Ash drawer 15 Leg frame 16 Adjustable foot bolts The hatches are supplied right hung but can be reversed so they are left hung A plate needs to be changed on the hatch to...

Страница 9: ...output 310 F Flue gas flow rate 0 11 lb s Operation natural ventilation fan with flue gas fan Condensing non condensing non condensing Positive negative pressure at flue gas outlet negative pressure P...

Страница 10: ...10 V rmebaronen Vedolux 55...

Страница 11: ...tandards It is important for all connection points and flues not to leak dust and gas If the boiler is connected higher up the chimney than a previous boiler was connected the lower inactive part must...

Страница 12: ...narrow pipe and the natural draught will not be enough to compensate for the long distance For the boiler to deliver the promised output the chim ney should not have an area that is too small or be t...

Страница 13: ...perature in the event of boiling Follow the valve manufacturer s installation instructions Filling heating system The boiler is fitted with valves for filling and draining Turbulators If the turbulato...

Страница 14: ...ion of a qualified electrician The boiler is connected to the fixed installation with rubber cable via an all pole main breaker with at least 0 12 in breaking distance The electrical connections are o...

Страница 15: ...wood is damp a large part of its energy is used to dry it combustion is impaired and the risk of tar coating increases On account of its high acid content firing with oak for extended periods of time...

Страница 16: ...here may be fire in the boiler 20 Main power switch 21 Thermostat for fan and charging pump 22 Starting the fan when the boiler is cold 25 Overheating protection Start 1 The bypass damper must be clos...

Страница 17: ...ontrolled by the draught that the fan creates and by the oxygen supply via the primary and secondary air that is supplied via the inner ash hatch To optimise combustion and efficiency the flue gas tem...

Страница 18: ...the end of the flue You can tell when it has reached the end because less force is required to move it Refit the turbulators Open the wood filling hatch and bypass damper Rake out the ash on the plate...

Страница 19: ...mber Scrape the ceramics softly and carefully when removing ash from the boiler Let a layer of ash of a few centimetres form a protective layer on the grate Fire only with real wood not plastic proces...

Страница 20: ...air valve is open Secondary air damper open too far If the damper is open too far the distribution between primary and secondary air is incorrect Start by having the secondary air damper completely cl...

Страница 21: ...nnection See points above Boiling sound in the boiler Low pressure head Check the pressure should be 14 5 psi The expansion tank must be adapted to the volume and the temperature variations that occur...

Страница 22: ...x 12 mm 8 x 6 9 x 0 5 in 3 310210 Front ceramic grate 1 310211 Rear ceramic grate 1 310212 Left ceramic duct 1 310213 Right ceramic duct 1 320007 Wood filling hatch 1 320017 Soot hatch 1 320020 Draug...

Страница 23: ......

Страница 24: ...V rmebaronen AB Arkelstorpsv gen 88 SE 291 94 Kristianstad Tel 46 44 22 63 20 Fax 46 44 22 63 58 www varmebaronen se www varmebaronen com info varmebaronen se...

Отзывы: