Function
Versatile
MP4 and MP6 G2 are wall-hung electric boilers with stain-
less steel boiler tanks and immersion heaters.
The boiler has many possibilities, such as underfloor heating
in extensions and conservatories, an easy way to heat the
holiday home or a freestanding garage, or for use in work
sheds, in holiday chalets and on campsites. The boiler is
extremely versatile.
With or without outdoor temperature compensation
The boiler is pre-set on delivery for outdoor temperature
compensated boiler temperature regulation, UTK, together
with an outdoor temperature sensor. The function can easily
be adjusted for a fixed boiler temperature regulation.
Compact
The MP4 and MP6 G2 are small in size and have a discreet
cover which make them easy to position.
Efficient
The boiler's power manages the heat required for up to 100
m² of living space, depending on insulation and ventilation.
Reliability
The boiler is equipped with a float switch to avoid damage to
the immersion heaters.
Alternate temperature or blocking
Potential-free input for change in UTK level or blocking
of boiler power, depending on the type of temperature
regulation selected.
Alarm indication
Alarms are indicated on the boiler's control panel, connection
is also available for an external buzzer alarm indication.
Complete
MP 4/6 is delivered complete. Only water and power need to
be connected. Then it is ready for use.
The boiler is equipped with:
- circulation pump
- expansion tank
- safety valve, 2.5 bar
- automatic vent valve
- overflow valve
- pressure gauge
- overheating protection
- status indications
- control switch
- float switch
- outdoor temperature sensor
Accessories
Room device
item no. 2964
Together with the boiler's UTK function, it also has a room
temperature effect on the temperature regulation.
GSM-control
item no. 1950
Remotely control the heat in, for example, the summer house
by turning on the heat from home.
Also automatically gives temperature alarms for the set limit
values and an alarm if the mains voltage disappears, which is
good to know if there is a risk of freezing.